{
"NDC": [
{
"NDCCode": "69945-894-14",
"PackageDescription": "1 INJECTION, SOLUTION in 1 CARTON (69945-894-14) ",
"NDC11Code": "69945-0894-14",
"ProductNDC": "69945-894",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Ultra-technekow",
"ProprietaryNameSuffix": "Dte",
"NonProprietaryName": "Technetium Tc-99m",
"DosageFormName": "INJECTION, SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20151207",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA017243",
"LabelerName": "Curium US LLC",
"SubstanceName": "TECHNETIUM TC-99M SODIUM PERTECHNETATE",
"StrengthNumber": "16",
"StrengthUnit": "Ci/1",
"Status": "Deprecated",
"LastUpdate": "2022-01-04",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20211231",
"StartMarketingDatePackage": "20151207",
"SamplePackage": "N"
},
{
"NDCCode": "69945-160-14",
"PackageDescription": "1 INJECTION, SOLUTION in 1 CARTON (69945-160-14) ",
"NDC11Code": "69945-0160-14",
"ProductNDC": "69945-160",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Ultra-technekow",
"ProprietaryNameSuffix": "V4",
"NonProprietaryName": "Technetium Tc-99m",
"DosageFormName": "INJECTION, SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20140610",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA017243",
"LabelerName": "Curium US LLC",
"SubstanceName": "TECHNETIUM TC-99M SODIUM PERTECHNETATE",
"StrengthNumber": "16",
"StrengthUnit": "Ci/1",
"Status": "Active",
"LastUpdate": "2024-10-19",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20140610",
"SamplePackage": "N",
"IndicationAndUsage": "The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.",
"Description": "The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution."
},
{
"NDCCode": "69945-140-13",
"PackageDescription": "1 INJECTION, SOLUTION in 1 CARTON (69945-140-13) ",
"NDC11Code": "69945-0140-13",
"ProductNDC": "69945-140",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Ultra-technekow",
"ProprietaryNameSuffix": "V4",
"NonProprietaryName": "Technetium Tc-99m",
"DosageFormName": "INJECTION, SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20140610",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA017243",
"LabelerName": "Curium US LLC",
"SubstanceName": "TECHNETIUM TC-99M SODIUM PERTECHNETATE",
"StrengthNumber": "14",
"StrengthUnit": "Ci/1",
"Status": "Active",
"LastUpdate": "2024-10-19",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20140610",
"SamplePackage": "N",
"IndicationAndUsage": "The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.",
"Description": "The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution."
},
{
"NDCCode": "69945-893-13",
"PackageDescription": "1 INJECTION, SOLUTION in 1 CARTON (69945-893-13) ",
"NDC11Code": "69945-0893-13",
"ProductNDC": "69945-893",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Ultra-technekow",
"ProprietaryNameSuffix": "Dte",
"NonProprietaryName": "Technetium Tc-99m",
"DosageFormName": "INJECTION, SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20151207",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA017243",
"LabelerName": "Curium US LLC",
"SubstanceName": "TECHNETIUM TC-99M SODIUM PERTECHNETATE",
"StrengthNumber": "14",
"StrengthUnit": "Ci/1",
"Status": "Deprecated",
"LastUpdate": "2022-01-04",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20211231",
"StartMarketingDatePackage": "20151207",
"SamplePackage": "N"
},
{
"NDCCode": "45865-894-49",
"PackageDescription": "100 TABLET, FILM COATED in 1 BOTTLE (45865-894-49) ",
"NDC11Code": "45865-0894-49",
"ProductNDC": "45865-894",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Rosuvastatin Calcium",
"NonProprietaryName": "Rosuvastatin Calcium",
"DosageFormName": "TABLET, FILM COATED",
"RouteName": "ORAL",
"StartMarketingDate": "20161031",
"MarketingCategoryName": "ANDA",
"ApplicationNumber": "ANDA206434",
"LabelerName": "medsource pharmaceuticals",
"SubstanceName": "ROSUVASTATIN CALCIUM",
"StrengthNumber": "40",
"StrengthUnit": "mg/1",
"Pharm_Classes": "HMG-CoA Reductase Inhibitor [EPC],Hydroxymethylglutaryl-CoA Reductase Inhibitors [MoA]",
"Status": "Deprecated",
"LastUpdate": "2020-01-01",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20191231",
"StartMarketingDatePackage": "20180601",
"SamplePackage": "N",
"IndicationAndUsage": "Pediatric use information for patients 7 to 17 years of age is approved for AstraZeneca’s CRESTOR (rosuvastatin calcium) tablets. However, due to AstraZeneca’s marketing exclusivity rights, this drug product is not labeled with that pediatric information.",
"Description": "Rosuvastatin calcium is a synthetic lipid-lowering agent for oral administration. The chemical name for rosuvastatin calcium is bis[(E)-7-[4-(4-fluorophenyl)-6-isopropyl-2-[methyl(methylsulfonyl)amino] pyrimidin-5-yl](3R,5S)-3,5-dihydroxyhept-6-enoic acid] calcium salt with the following structural formula. The empirical formula for rosuvastatin calcium is (C 22H 27FN 3O 6S) 2Ca and the molecular weight is 1001.14. Rosuvastatin calcium is a white amorphous powder that is sparingly soluble in water and methanol, and slightly soluble in ethanol. Rosuvastatin calcium is a hydrophilic compound with a partition coefficient (octanol/water) of 0.13 at pH of 7.0. Rosuvastatin calcium tablets for oral administration contain 5, 10, 20, or 40 mg of rosuvastatin and the following inactive ingredients: For 5 mg: Each film coated tablet contains: microcrystalline cellulose, lactose monohydrate, anhydrous lactose, crospovidone, magnesium oxide, magnesium stearate, hypromellose, triacetin, titanium dioxide, and ferric oxide yellow. For 10, 20 and 40 mg: Each film coated tablet contains: microcrystalline cellulose, lactose monohydrate, anhydrous lactose, crospovidone, magnesium oxide, magnesium stearate, hypromellose, triacetin, titanium dioxide, FD & C yellow No. 6, FD & C red No. 40, and FD & C blue No.1."
},
{
"NDCCode": "58160-894-15",
"PackageDescription": "1 KIT in 1 CARTON (58160-894-15) * .5 mL in 1 VIAL (58160-719-03) * .5 mL in 1 SYRINGE (58160-749-07) ",
"NDC11Code": "58160-0894-15",
"ProductNDC": "58160-894",
"ProductTypeName": "VACCINE",
"ProprietaryName": "Arexvy",
"NonProprietaryName": "Respiratory Syncytial Virus Vaccine Recombinant, Adjuvanted",
"DosageFormName": "KIT",
"StartMarketingDate": "20260430",
"MarketingCategoryName": "BLA",
"ApplicationNumber": "BLA125775",
"LabelerName": "GlaxoSmithKline Biologicals SA",
"Status": "Active",
"LastUpdate": "2026-08-11",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20260430",
"SamplePackage": "N",
"IndicationAndUsage": "AREXVY is a vaccine indicated for active immunization for the prevention of lower respiratory tract disease (LRTD) caused by respiratory syncytial virus (RSV) in: 1 individuals 60 years of age and older;, 2 individuals 18 through 59 years of age who are at increased risk for LRTD caused by RSV.",
"Description": "AREXVY (Respiratory Syncytial Virus Vaccine, Adjuvanted) is a sterile injectable suspension for intramuscular use. The vaccine is supplied as a vial of lyophilized recombinant respiratory syncytial virus glycoprotein F stabilized in pre‑fusion conformation (RSVPreF3) as the antigen component, which must be reconstituted at the time of use with the accompanying vial or prefilled syringe of AS01E adjuvant as the Adjuvant Suspension Component. The RSVPreF3 antigen is expressed by culturing genetically engineered Chinese Hamster Ovary cells in media containing no antibiotics or animal‑derived proteins. The RSVPreF3 protein is purified by several chromatographic and filtration steps, formulated with excipients, filled into vials, and lyophilized. The AS01E adjuvant is composed of 3‑O‑desacyl‑4’‑monophosphoryl lipid A (MPL) from Salmonella minnesota and QS‑21, a saponin purified from plant extract Quillaja saponaria Molina, combined in a liposomal formulation. The liposomes are composed of dioleoyl phosphatidylcholine (DOPC) and cholesterol in a phosphate‑buffered saline solution containing disodium phosphate anhydrous, potassium dihydrogen phosphate, sodium chloride, and water for injection. After reconstitution of the vial and vial presentation, each 0.5 mL dose is formulated to contain 120 mcg of the recombinant RSVPreF3 antigen, 25 mcg of MPL, and 25 mcg of QS‑21. Each dose also contains 14.7 mg of Trehalose, 4.4 mg of sodium chloride, 0.83 mg of potassium dihydrogen phosphate, 0.26 mg of dipotassium phosphate, 0.18 mg of polysorbate 80, 0.15 mg of disodium phosphate anhydrous, 0.5 mg of DOPC, and 0.125 mg of cholesterol. After reconstitution of the vial and prefilled syringe presentation, each dose (approximately 0.5 mL) is formulated to contain 120 mcg of the recombinant RSVPreF3 antigen, 25 mcg of MPL, and 25 mcg of QS‑21. Each dose also contains 16.3 mg of Trehalose, 4.4 mg of sodium chloride, 0.87 mg of potassium dihydrogen phosphate, 0.29 mg of dipotassium phosphate, 0.20 mg of polysorbate 80, 0.15 mg of disodium phosphate anhydrous, 0.5 mg of DOPC, and 0.125 mg of cholesterol. AREXVY contains no preservative. Each dose may also contain residual amounts of host cell proteins (≤2.0%) and DNA (≤0.80 ng/mg) from the manufacturing process. The stopper of the vial containing Lyophilized Antigen Component or Adjuvant Suspension Component and the tip cap and plunger stopper of the prefilled syringe containing Adjuvant Suspension Component are not made with natural rubber latex."
},
{
"NDCCode": "62135-894-90",
"PackageDescription": "90 CAPSULE in 1 BOTTLE (62135-894-90) ",
"NDC11Code": "62135-0894-90",
"ProductNDC": "62135-894",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Fenofibrate",
"NonProprietaryName": "Fenofibrate",
"DosageFormName": "CAPSULE",
"RouteName": "ORAL",
"StartMarketingDate": "20240131",
"MarketingCategoryName": "ANDA",
"ApplicationNumber": "ANDA211407",
"LabelerName": "Chartwell RX, LLC.",
"SubstanceName": "FENOFIBRATE",
"StrengthNumber": "134",
"StrengthUnit": "mg/1",
"Pharm_Classes": "Peroxisome Proliferator Receptor alpha Agonist [EPC]",
"Status": "Active",
"LastUpdate": "2025-12-16",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20261231",
"StartMarketingDatePackage": "20240912",
"SamplePackage": "N",
"IndicationAndUsage": "Treatment of Hypercholesterolemia. Fenofibrate capsules are indicated as adjunctive therapy to diet for the reduction of LDL-C, Total-C, Triglycerides and apo B in adult patients with primary hypercholesterolemia or mixed dyslipidemia (Fredrickson Types IIa and IIb). Lipid-altering agents should be used in addition to a diet restricted in saturated fat and cholesterol when response to diet and non-pharmacological interventions alone has been inadequate (see National Cholesterol Education Program [NCEP] Treatment Guidelines, below). Treatment of Hypertriglyceridemia. Fenofibrate capsules are also indicated as adjunctive therapy to diet for treatment of adult patients with hypertriglyceridemia (Fredrickson Types IV and V hyperlipidemia). Improving glycemic control in diabetic patients showing fasting chylomicronemia will usually reduce fasting triglycerides and eliminate chylomicronemia thereby obviating the need for pharmacologic intervention. Markedly elevated levels of serum triglycerides (e.g. > 2,000 mg/dL) may increase the risk of developing pancreatitis. The effect of fenofibrate therapy on reducing this risk has not been adequately studied. Drug therapy is not indicated for patients with Type I hyperlipoproteinemia, who have elevations of chylomicrons and plasma triglycerides, but who have normal levels of very low density lipoprotein (VLDL). Inspection of plasma refrigerated for 14 hours is helpful in distinguishing Types I, IV and V hyperlipoproteinemia 2. The initial treatment for dyslipidemia is dietary therapy specific for the type of lipoprotein abnormality. Excess body weight and excess alcoholic intake may be important factors in hypertriglyceridemia and should be addressed prior to any drug therapy. Physical exercise can be an important ancillary measure. Diseases contributory to hyperlipidemia, such as hypothyroidism or diabetes mellitus should be looked for and adequately treated. Estrogen therapy, like thiazide diuretics and beta-blockers, is sometimes associated with massive rises in plasma triglycerides, especially in subjects with familial hypertriglyceridemia. In such cases, discontinuation of the specific etiologic agent may obviate the need for specific drug therapy of hypertriglyceridemia. The use of drugs should be considered only when reasonable attempts have been made to obtain satisfactory results with non-drug methods. If the decision is made to use drugs, the patient should be instructed that this does not reduce the importance of adhering to diet (see WARNINGSand PRECAUTIONS). Fredrickson Classification of Hyperlipoproteinemias. C = cholesterol TG = triglycerides. LDL = low density lipoprotein. VLDL = very low density lipoprotein. IDL = intermediate density lipoprotein. The NCEP Treatment Guidelines. a Coronary heart disease or peripheral vascular disease (including symptomatic carotid artery disease). b Other risk factors for coronary heart disease (CHD) include: age (males: ≥ 4 5 years; females: ≥ 55 years or premature menopause without estrogen replacement therapy); family history of premature CHD; current cigarette smoking; hypertension; confirmed HDL- C <35 mg/dL (<0.91mmol/L); and diabetes mellitus. Subtract 1 risk factor if HDL-C is ≥ 60 mg/dL (≥1.6 mmol/L). c In CHD patients with LDL-C levels 100 to 129 mg/dL, the physician should exercise clinical judgment in deciding whether to initiate drug treatment.",
"Description": "Fenofibrate USP, (micronized) is a lipid regulating agent available as capsules for oral administration. Each capsule contains 67 mg, 134 mg or 200 mg of micronized fenofibrate. The chemical name for fenofibrate is 2-[4-(4-chlorobenzoyl) phenoxy]-2-methyl-propanoic acid, 1- methylethyl ester with the following structural formula. The empirical formula is C 20H 21O 4Cl and the molecular weight is 360.83; fenofibrate is insoluble in water. The melting point is 79-82°C. Fenofibrate is a white solid which is stable under ordinary conditions. Inactive Ingredients:The inactive ingredients in fenofibrate capsules include lactose monohydrate, crospovidone, pregelatinized starch, povidone, sodium lauryl sulfate and magnesium stearate. The capsule shells contain gelatin, titanium dioxide, FD&C Blue # 1, and FD#C Red #3. Additionally, the capsule imprint ink contains shellac, dehydrated alcohol, isopropyl alcohol, butyl alcohol, propylene glycol, strong ammonium solution, black iron oxide, potassium hydroxide and purified water."
},
{
"NDCCode": "68180-894-73",
"PackageDescription": "3 POUCH in 1 CARTON (68180-894-73) / 1 BLISTER PACK in 1 POUCH / 1 KIT in 1 BLISTER PACK",
"NDC11Code": "68180-0894-73",
"ProductNDC": "68180-894",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Drospirenone, Ethinyl Estradiol And Levomefolate Calcium And Levomefolate Calcium",
"NonProprietaryName": "Drospirenone, Ethinyl Estradiol And Levomefolate Calcium And Levomefolate Calcium",
"DosageFormName": "KIT",
"StartMarketingDate": "20180822",
"MarketingCategoryName": "ANDA",
"ApplicationNumber": "ANDA205947",
"LabelerName": "Lupin Pharmaceuticals, Inc.",
"Status": "Active",
"LastUpdate": "2025-12-16",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20261231",
"StartMarketingDatePackage": "20180822",
"SamplePackage": "N",
"IndicationAndUsage": "Drospirenone, ethinyl estradiol and levomefolate calcium tablet and levomefolate calcium tablet is a combination of drospirenone, a progestin and ethinyl estradiol, an estrogen containing a folate, indicated for use by females of reproductive potential to: 1 Prevent pregnancy. (1.1), 2 Treat symptoms of premenstrual dysphoric disorder (PMDD) for females of reproductive potential who choose to use an oral contraceptive for contraception. (1.2), 3 Treat moderate acne for females of reproductive potential at least 14 years old only if the patient desires an oral contraceptive for birth control. (1.3), 4 Raise folate levels in females of reproductive potential who choose to use an oral contraceptive for contraception. (1.4).",
"Description": "Drospirenone, ethinyl estradiol and levomefolate calcium tablets and levomefolate calcium tablets provide an oral contraceptive regimen consisting of 28 film-coated tablets that contain the active ingredients specified for each tablet below: 1 24 pink tablets each containing 3 mg DRSP, 0.02 mg EE, and 0.451 mg levomefolate calcium, 2 4 light orange tablets each containing 0.451 mg levomefolate calcium."
},
{
"NDCCode": "69097-894-02",
"PackageDescription": "30 CAPSULE in 1 BOTTLE, PLASTIC (69097-894-02) ",
"NDC11Code": "69097-0894-02",
"ProductNDC": "69097-894",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Fenofibrate",
"NonProprietaryName": "Fenofibrate",
"DosageFormName": "CAPSULE",
"RouteName": "ORAL",
"StartMarketingDate": "20170330",
"MarketingCategoryName": "ANDA",
"ApplicationNumber": "ANDA207378",
"LabelerName": "Cipla USA Inc.,",
"SubstanceName": "FENOFIBRATE",
"StrengthNumber": "67",
"StrengthUnit": "mg/1",
"Pharm_Classes": "Peroxisome Proliferator Receptor alpha Agonist [EPC]",
"Status": "Active",
"LastUpdate": "2023-01-24",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20170330",
"SamplePackage": "N",
"IndicationAndUsage": "Treatment of Hypercholesterolemia. Fenofibrate capsules, USP are indicated as adjunctive therapy to diet for the reduction of LDLC, total-C, Triglycerides and apo B in adult patients with primary hypercholesterolemia or mixed dyslipidemia (Fredrickson Types IIa and IIb). Lipid altering agents should be used in addition to a diet restricted in saturated fat and cholesterol when response to diet and non-pharmacological interventions alone has been inadequate (see National Cholesterol Education Program [NCEP] Treatment Guidelines, below). Treatment of Hypertriglyceridemia. Fenofibrate capsules, USP are also indicated as adjunctive therapy to diet for treatment of adult patients with hypertriglyceridemia (Fredrickson Types IV and V hyperlipidemia). Improving glycemic control in diabetic patients showing fasting chylomicronemia will usually reduce fasting triglycerides and eliminate chylomicronemia thereby obviating the need for pharmacologic intervention. Markedly elevated levels of serum triglycerides (e.g. > 2,000 mg/dL) may increase the risk of developing pancreatitis. The effect of fenofibrate therapy on reducing this risk has not been adequately studied. Drug therapy is not indicated for patients with Type I hyperlipoproteinemia, who have elevations of chylomicrons and plasma triglycerides, but who have normal levels of very low density lipoprotein (VLDL). Inspection of plasma refrigerated for 14 hours is helpful in distinguishing Types I, IV and V hyperlipoproteinemia2. The initial treatment for dyslipidemia is dietary therapy specific for the type of lipoprotein abnormality. Excess body weight and excess alcoholic intake may be important factors in hypertriglyceridemia and should be addressed prior to any drug therapy. Physical exercise can be an important ancillary measure. Diseases contributory to hyperlipidemia, such as hypothyroidism or diabetes mellitus should be looked for and adequately treated. Estrogen therapy, like thiazide diuretics and beta-blockers, is sometimes associated with massive rises in plasma triglycerides, especially in subjects with familial hypertriglyceridemia. In such cases, discontinuation of the specific etiologic agent may obviate the need for specific drug therapy of hypertriglyceridemia. The use of drugs should be considered only when reasonable attempts have been made to obtain satisfactory results with non-drug methods. If the decision is made to use drugs, the patient should be instructed that this does not reduce the importance of adhering to diet (See WARNINGS and PRECAUTIONS).",
"Description": "Fenofibrate capsules, USP (micronized) are a lipid regulating agent available as capsules for oral administration. The chemical name for fenofibrate is 2-[4-(4-chlorobenzoyl) phenoxy]-2- methylpropanoic acid, 1-methylethyl ester with the following structural formula. The molecular formula is C20H21O4Cl and the molecular weight is 360.83; fenofibrate is insoluble in water. The melting point is 79° to 82°C. Fenofibrate, USP is a white solid which is stable under ordinary conditions. Each 67 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, FD&C Red No.3, D&C Yellow No.10, titanium dioxide and gelatin. Each 134 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, D&C Red No.28, titanium dioxide and gelatin. Each 200 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, FD&C Red No.40, FD&C Yellow No.6, titanium dioxide and gelatin. The imprinting ink contains shellac, dehydrated alcohol, isopropyl alcohol, butyl alcohol, propylene glycol, strong ammonia solution, black iron oxide, potassium hydroxide and purified water. USP dissolution test is pending."
},
{
"NDCCode": "69097-894-07",
"PackageDescription": "100 CAPSULE in 1 BOTTLE, PLASTIC (69097-894-07) ",
"NDC11Code": "69097-0894-07",
"ProductNDC": "69097-894",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Fenofibrate",
"NonProprietaryName": "Fenofibrate",
"DosageFormName": "CAPSULE",
"RouteName": "ORAL",
"StartMarketingDate": "20170330",
"MarketingCategoryName": "ANDA",
"ApplicationNumber": "ANDA207378",
"LabelerName": "Cipla USA Inc.,",
"SubstanceName": "FENOFIBRATE",
"StrengthNumber": "67",
"StrengthUnit": "mg/1",
"Pharm_Classes": "Peroxisome Proliferator Receptor alpha Agonist [EPC]",
"Status": "Active",
"LastUpdate": "2023-01-24",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20170330",
"SamplePackage": "N",
"IndicationAndUsage": "Treatment of Hypercholesterolemia. Fenofibrate capsules, USP are indicated as adjunctive therapy to diet for the reduction of LDLC, total-C, Triglycerides and apo B in adult patients with primary hypercholesterolemia or mixed dyslipidemia (Fredrickson Types IIa and IIb). Lipid altering agents should be used in addition to a diet restricted in saturated fat and cholesterol when response to diet and non-pharmacological interventions alone has been inadequate (see National Cholesterol Education Program [NCEP] Treatment Guidelines, below). Treatment of Hypertriglyceridemia. Fenofibrate capsules, USP are also indicated as adjunctive therapy to diet for treatment of adult patients with hypertriglyceridemia (Fredrickson Types IV and V hyperlipidemia). Improving glycemic control in diabetic patients showing fasting chylomicronemia will usually reduce fasting triglycerides and eliminate chylomicronemia thereby obviating the need for pharmacologic intervention. Markedly elevated levels of serum triglycerides (e.g. > 2,000 mg/dL) may increase the risk of developing pancreatitis. The effect of fenofibrate therapy on reducing this risk has not been adequately studied. Drug therapy is not indicated for patients with Type I hyperlipoproteinemia, who have elevations of chylomicrons and plasma triglycerides, but who have normal levels of very low density lipoprotein (VLDL). Inspection of plasma refrigerated for 14 hours is helpful in distinguishing Types I, IV and V hyperlipoproteinemia2. The initial treatment for dyslipidemia is dietary therapy specific for the type of lipoprotein abnormality. Excess body weight and excess alcoholic intake may be important factors in hypertriglyceridemia and should be addressed prior to any drug therapy. Physical exercise can be an important ancillary measure. Diseases contributory to hyperlipidemia, such as hypothyroidism or diabetes mellitus should be looked for and adequately treated. Estrogen therapy, like thiazide diuretics and beta-blockers, is sometimes associated with massive rises in plasma triglycerides, especially in subjects with familial hypertriglyceridemia. In such cases, discontinuation of the specific etiologic agent may obviate the need for specific drug therapy of hypertriglyceridemia. The use of drugs should be considered only when reasonable attempts have been made to obtain satisfactory results with non-drug methods. If the decision is made to use drugs, the patient should be instructed that this does not reduce the importance of adhering to diet (See WARNINGS and PRECAUTIONS).",
"Description": "Fenofibrate capsules, USP (micronized) are a lipid regulating agent available as capsules for oral administration. The chemical name for fenofibrate is 2-[4-(4-chlorobenzoyl) phenoxy]-2- methylpropanoic acid, 1-methylethyl ester with the following structural formula. The molecular formula is C20H21O4Cl and the molecular weight is 360.83; fenofibrate is insoluble in water. The melting point is 79° to 82°C. Fenofibrate, USP is a white solid which is stable under ordinary conditions. Each 67 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, FD&C Red No.3, D&C Yellow No.10, titanium dioxide and gelatin. Each 134 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, D&C Red No.28, titanium dioxide and gelatin. Each 200 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, FD&C Red No.40, FD&C Yellow No.6, titanium dioxide and gelatin. The imprinting ink contains shellac, dehydrated alcohol, isopropyl alcohol, butyl alcohol, propylene glycol, strong ammonia solution, black iron oxide, potassium hydroxide and purified water. USP dissolution test is pending."
},
{
"NDCCode": "69097-894-15",
"PackageDescription": "1000 CAPSULE in 1 BOTTLE, PLASTIC (69097-894-15) ",
"NDC11Code": "69097-0894-15",
"ProductNDC": "69097-894",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Fenofibrate",
"NonProprietaryName": "Fenofibrate",
"DosageFormName": "CAPSULE",
"RouteName": "ORAL",
"StartMarketingDate": "20170330",
"MarketingCategoryName": "ANDA",
"ApplicationNumber": "ANDA207378",
"LabelerName": "Cipla USA Inc.,",
"SubstanceName": "FENOFIBRATE",
"StrengthNumber": "67",
"StrengthUnit": "mg/1",
"Pharm_Classes": "Peroxisome Proliferator Receptor alpha Agonist [EPC]",
"Status": "Active",
"LastUpdate": "2023-01-24",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20170330",
"SamplePackage": "N",
"IndicationAndUsage": "Treatment of Hypercholesterolemia. Fenofibrate capsules, USP are indicated as adjunctive therapy to diet for the reduction of LDLC, total-C, Triglycerides and apo B in adult patients with primary hypercholesterolemia or mixed dyslipidemia (Fredrickson Types IIa and IIb). Lipid altering agents should be used in addition to a diet restricted in saturated fat and cholesterol when response to diet and non-pharmacological interventions alone has been inadequate (see National Cholesterol Education Program [NCEP] Treatment Guidelines, below). Treatment of Hypertriglyceridemia. Fenofibrate capsules, USP are also indicated as adjunctive therapy to diet for treatment of adult patients with hypertriglyceridemia (Fredrickson Types IV and V hyperlipidemia). Improving glycemic control in diabetic patients showing fasting chylomicronemia will usually reduce fasting triglycerides and eliminate chylomicronemia thereby obviating the need for pharmacologic intervention. Markedly elevated levels of serum triglycerides (e.g. > 2,000 mg/dL) may increase the risk of developing pancreatitis. The effect of fenofibrate therapy on reducing this risk has not been adequately studied. Drug therapy is not indicated for patients with Type I hyperlipoproteinemia, who have elevations of chylomicrons and plasma triglycerides, but who have normal levels of very low density lipoprotein (VLDL). Inspection of plasma refrigerated for 14 hours is helpful in distinguishing Types I, IV and V hyperlipoproteinemia2. The initial treatment for dyslipidemia is dietary therapy specific for the type of lipoprotein abnormality. Excess body weight and excess alcoholic intake may be important factors in hypertriglyceridemia and should be addressed prior to any drug therapy. Physical exercise can be an important ancillary measure. Diseases contributory to hyperlipidemia, such as hypothyroidism or diabetes mellitus should be looked for and adequately treated. Estrogen therapy, like thiazide diuretics and beta-blockers, is sometimes associated with massive rises in plasma triglycerides, especially in subjects with familial hypertriglyceridemia. In such cases, discontinuation of the specific etiologic agent may obviate the need for specific drug therapy of hypertriglyceridemia. The use of drugs should be considered only when reasonable attempts have been made to obtain satisfactory results with non-drug methods. If the decision is made to use drugs, the patient should be instructed that this does not reduce the importance of adhering to diet (See WARNINGS and PRECAUTIONS).",
"Description": "Fenofibrate capsules, USP (micronized) are a lipid regulating agent available as capsules for oral administration. The chemical name for fenofibrate is 2-[4-(4-chlorobenzoyl) phenoxy]-2- methylpropanoic acid, 1-methylethyl ester with the following structural formula. The molecular formula is C20H21O4Cl and the molecular weight is 360.83; fenofibrate is insoluble in water. The melting point is 79° to 82°C. Fenofibrate, USP is a white solid which is stable under ordinary conditions. Each 67 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, FD&C Red No.3, D&C Yellow No.10, titanium dioxide and gelatin. Each 134 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, D&C Red No.28, titanium dioxide and gelatin. Each 200 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, FD&C Red No.40, FD&C Yellow No.6, titanium dioxide and gelatin. The imprinting ink contains shellac, dehydrated alcohol, isopropyl alcohol, butyl alcohol, propylene glycol, strong ammonia solution, black iron oxide, potassium hydroxide and purified water. USP dissolution test is pending."
},
{
"NDCCode": "69945-010-03",
"PackageDescription": "1 INJECTION, SOLUTION in 1 CARTON (69945-010-03) ",
"NDC11Code": "69945-0010-03",
"ProductNDC": "69945-010",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Ultra-technekow",
"ProprietaryNameSuffix": "V4",
"NonProprietaryName": "Technetium Tc-99m",
"DosageFormName": "INJECTION, SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20140610",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA017243",
"LabelerName": "Curium US LLC",
"SubstanceName": "TECHNETIUM TC-99M SODIUM PERTECHNETATE",
"StrengthNumber": "1",
"StrengthUnit": "Ci/1",
"Status": "Active",
"LastUpdate": "2024-10-19",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20140610",
"SamplePackage": "N",
"IndicationAndUsage": "The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.",
"Description": "The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution."
},
{
"NDCCode": "69945-015-04",
"PackageDescription": "1 INJECTION, SOLUTION in 1 CARTON (69945-015-04) ",
"NDC11Code": "69945-0015-04",
"ProductNDC": "69945-015",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Ultra-technekow",
"ProprietaryNameSuffix": "V4",
"NonProprietaryName": "Technetium Tc-99m",
"DosageFormName": "INJECTION, SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20140610",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA017243",
"LabelerName": "Curium US LLC",
"SubstanceName": "TECHNETIUM TC-99M SODIUM PERTECHNETATE",
"StrengthNumber": "1.5",
"StrengthUnit": "Ci/1",
"Status": "Active",
"LastUpdate": "2024-10-19",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20140610",
"SamplePackage": "N",
"IndicationAndUsage": "The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.",
"Description": "The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution."
},
{
"NDCCode": "69945-020-05",
"PackageDescription": "1 INJECTION, SOLUTION in 1 CARTON (69945-020-05) ",
"NDC11Code": "69945-0020-05",
"ProductNDC": "69945-020",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Ultra-technekow",
"ProprietaryNameSuffix": "V4",
"NonProprietaryName": "Technetium Tc-99m",
"DosageFormName": "INJECTION, SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20140610",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA017243",
"LabelerName": "Curium US LLC",
"SubstanceName": "TECHNETIUM TC-99M SODIUM PERTECHNETATE",
"StrengthNumber": "2",
"StrengthUnit": "Ci/1",
"Status": "Active",
"LastUpdate": "2024-10-19",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20140610",
"SamplePackage": "N",
"IndicationAndUsage": "The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.",
"Description": "The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution."
},
{
"NDCCode": "69945-025-06",
"PackageDescription": "1 INJECTION, SOLUTION in 1 CARTON (69945-025-06) ",
"NDC11Code": "69945-0025-06",
"ProductNDC": "69945-025",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Ultra-technekow",
"ProprietaryNameSuffix": "V4",
"NonProprietaryName": "Technetium Tc-99m",
"DosageFormName": "INJECTION, SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20140610",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA017243",
"LabelerName": "Curium US LLC",
"SubstanceName": "TECHNETIUM TC-99M SODIUM PERTECHNETATE",
"StrengthNumber": "2.5",
"StrengthUnit": "Ci/1",
"Status": "Active",
"LastUpdate": "2024-10-19",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20140610",
"SamplePackage": "N",
"IndicationAndUsage": "The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.",
"Description": "The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution."
},
{
"NDCCode": "69945-030-07",
"PackageDescription": "1 INJECTION, SOLUTION in 1 CARTON (69945-030-07) ",
"NDC11Code": "69945-0030-07",
"ProductNDC": "69945-030",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Ultra-technekow",
"ProprietaryNameSuffix": "V4",
"NonProprietaryName": "Technetium Tc-99m",
"DosageFormName": "INJECTION, SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20140610",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA017243",
"LabelerName": "Curium US LLC",
"SubstanceName": "TECHNETIUM TC-99M SODIUM PERTECHNETATE",
"StrengthNumber": "3",
"StrengthUnit": "Ci/1",
"Status": "Active",
"LastUpdate": "2024-10-19",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20140610",
"SamplePackage": "N",
"IndicationAndUsage": "The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.",
"Description": "The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution."
},
{
"NDCCode": "69945-035-08",
"PackageDescription": "1 INJECTION, SOLUTION in 1 CARTON (69945-035-08) ",
"NDC11Code": "69945-0035-08",
"ProductNDC": "69945-035",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Ultra-technekow",
"ProprietaryNameSuffix": "V4",
"NonProprietaryName": "Technetium Tc-99m",
"DosageFormName": "INJECTION, SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20140610",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA017243",
"LabelerName": "Curium US LLC",
"SubstanceName": "TECHNETIUM TC-99M SODIUM PERTECHNETATE",
"StrengthNumber": "3.5",
"StrengthUnit": "Ci/1",
"Status": "Active",
"LastUpdate": "2024-10-19",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20140610",
"SamplePackage": "N",
"IndicationAndUsage": "The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.",
"Description": "The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution."
},
{
"NDCCode": "69945-050-40",
"PackageDescription": "1 KIT in 1 BOX (69945-050-40) * 1 mL in 1 VIAL, GLASS * 1 mL in 1 VIAL, GLASS",
"NDC11Code": "69945-0050-40",
"ProductNDC": "69945-050",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Octreoscan",
"NonProprietaryName": "Indium In -111 Pentetreotide",
"DosageFormName": "KIT",
"StartMarketingDate": "20151014",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA020314",
"LabelerName": "Curium US LLC",
"Status": "Active",
"LastUpdate": "2022-02-23",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20151014",
"SamplePackage": "N",
"IndicationAndUsage": "Octreoscan, after radiolabeling, is an agent for the scintigraphic localization of primary and metastatic neuroendocrine tumors bearing somatostatin receptors.",
"Description": "Octreoscan is a kit for the preparation of Indium In 111 Pentetreotide Injection, a radioactive diagnostic agent. It is a kit consisting of two components. 1) A 10-mL Octreoscan Reaction Vial which contains a lyophilized mixture of: (i) 10 mcg pentetreotide [N-(diethylenetriamine-N,N,N′,N″-tetraacetic acid-N″-acetyl)-D-phenylalanyl-L-hemicystyl-L-phenylalanyl-D-tryptophyl-L-lysyl-L-threonyl-L-hemicystyl-L-threoninol cyclic (2→7) disulfide], (also known as octreotide DTPA), (ii) 2 mg gentisic acid [2, 5-dihydroxybenzoic acid], (iii) 4.9 mg trisodium citrate, anhydrous, (iv) 0.37 mg citric acid, anhydrous, and (v) 10 mg inositol. Pentetreotide has the following structural formula. Prior to lyophilization, sodium hydroxide or hydrochloric acid may have been added for pH adjustment. The vial contents are sterile and nonpyrogenic. No bacteriostatic preservative is present. 2) A 10-mL vial of Indium In 111 Chloride Solution, which contains: 1.1 mL or 111 MBq/mL (3 mCi/mL) indium In 111 chloride in 0.02N HCl at time of calibration. The vial also contains ferric chloride at a concentration of 3.5 mcg/mL (ferric ion, 1.2 mcg/mL). The vial contents are sterile and nonpyrogenic. No bacteriostatic preservative is present. Indium In 111 Pentetreotide Injection is prepared by combining the two kit components (see INSTRUCTIONS FOR THE PREPARATION OF INDIUM In 111 PENTETREOTIDE INJECTION). Indium In-111 reacts with the diethylenetriaminetetraacetic acid portion of the pentetreotide molecule to form indium In 111 pentetreotide. The pH of the resultant Indium In 111 Pentetreotide Injection is between 3.8 and 4.3. No bacteriostatic preservative is present. The Indium In 111 Pentetreotide Injection is suitable for intravenous administration as is, or it may be diluted to a maximum volume of 3 mL with 0.9% Sodium Chloride Injection, USP, immediately before intravenous administration. In either case, the radiolabeling yield of Indium In 111 Pentetreotide Injection should be determined before administration to the patient. A method recommended for determining the radiolabeling yield is presented at the end of this package insert (see RECOMMENDED METHOD FOR DETERMINATION OF RADIOLABELING YIELD OF INDIUM In 111 PENTETREOTIDE INJECTION)."
},
{
"NDCCode": "69945-051-09",
"PackageDescription": "1 INJECTION, SOLUTION in 1 CARTON (69945-051-09) ",
"NDC11Code": "69945-0051-09",
"ProductNDC": "69945-051",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Ultra-technekow",
"ProprietaryNameSuffix": "V4",
"NonProprietaryName": "Technetium Tc-99m",
"DosageFormName": "INJECTION, SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20140610",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA017243",
"LabelerName": "Curium US LLC",
"SubstanceName": "TECHNETIUM TC-99M SODIUM PERTECHNETATE",
"StrengthNumber": "5",
"StrengthUnit": "Ci/1",
"Status": "Active",
"LastUpdate": "2024-10-19",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20140610",
"SamplePackage": "N",
"IndicationAndUsage": "The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.",
"Description": "The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution."
},
{
"NDCCode": "69945-060-10",
"PackageDescription": "1 INJECTION, SOLUTION in 1 CARTON (69945-060-10) ",
"NDC11Code": "69945-0060-10",
"ProductNDC": "69945-060",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Ultra-technekow",
"ProprietaryNameSuffix": "V4",
"NonProprietaryName": "Technetium Tc-99m",
"DosageFormName": "INJECTION, SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20140610",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA017243",
"LabelerName": "Curium US LLC",
"SubstanceName": "TECHNETIUM TC-99M SODIUM PERTECHNETATE",
"StrengthNumber": "6",
"StrengthUnit": "Ci/1",
"Status": "Active",
"LastUpdate": "2024-10-19",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20140610",
"SamplePackage": "N",
"IndicationAndUsage": "The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.",
"Description": "The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution."
},
{
"NDCCode": "69945-064-01",
"PackageDescription": "1 VIAL, SINGLE-USE in 1 CAN (69945-064-01) / 4 mL in 1 VIAL, SINGLE-USE",
"NDC11Code": "69945-0064-01",
"ProductNDC": "69945-064",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Detectnet",
"NonProprietaryName": "Copper Cu 64 Dotatate",
"DosageFormName": "INJECTION, SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20200914",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA213227",
"LabelerName": "CURIUM US LLC",
"SubstanceName": "COPPER OXODOTREOTIDE CU-64",
"StrengthNumber": "1",
"StrengthUnit": "mCi/mL",
"Pharm_Classes": "Positron Emitting Activity [MoA], Radioactive Diagnostic Agent [EPC]",
"Status": "Active",
"LastUpdate": "2025-02-04",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20200914",
"SamplePackage": "N",
"IndicationAndUsage": "Detectnet is indicated for use with positron emission tomography (PET) for localization of somatostatin receptor positive neuroendocrine tumors (NETs) in adult patients."
},
{
"NDCCode": "69945-068-20",
"PackageDescription": "5 CELLO PACK in 1 BOX (69945-068-20) / 1 KIT in 1 CELLO PACK (69945-068-10) * .6 mL in 1 SYRINGE, GLASS * 1 mL in 1 SYRINGE, GLASS * 9.5 mg in 1 VIAL, GLASS",
"NDC11Code": "69945-0068-20",
"ProductNDC": "69945-068",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Ultratag",
"ProprietaryNameSuffix": "Rbc",
"NonProprietaryName": "Kit For The Preparation Of Technetium Tc 99m Red Blood Cells",
"DosageFormName": "KIT",
"StartMarketingDate": "19910610",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA019981",
"LabelerName": "Curium US LLC",
"Status": "Active",
"LastUpdate": "2025-07-04",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "19910610",
"SamplePackage": "N",
"IndicationAndUsage": "Technetium Tc 99m red blood cells are used for blood pool imaging, including cardiac first pass and gated equilibrium imaging and for detection of sites of gastrointestinal bleeding.",
"Description": "Ultratag RBC (Kit for the Preparation of Technetium Tc 99m Red Blood Cells Injection) is a sterile, nonpyrogenic, diagnostic kit for the in vitro preparation of Technetium Tc 99m Red Blood Cells Injection. Each kit consists of three separate nonradioactive components. 1. A 10 milliliter reaction vial containing. Stannous Chloride, Dihydrate (SnCl 22H 2O) – 50 mcg minimum. Stannous Chloride, Dihydrate (SnCl 22H 2O) – 96 mcg theoretical. Tin Chloride (Stannous and Stannic), Dihydrate (as SnCl 22H 2O) – 105 mcg maximum. Sodium Citrate, Dihydrate – 3.67 mg. Dextrose, Anhydrous – 5.5 mg. Hydrochloric Acid – 0.47 mg. Prior to lyophilization, the pH is adjusted to 7.1 to 7.2 with sodium hydroxide. The contents of the vial are lyophilized and stored under argon. 2. Syringe I contains. Sodium Hypochlorite – 0.6 mg in Sterile Water for Injection. The total volume of this syringe is 0.6 mL. Sodium hydroxide may have been added for pH adjustment. The pH of this solution is 11 to 13. The syringe must be protected from light to prevent degradation of the light-sensitive sodium hypochlorite. 3. Syringe II contains. Citric Acid, Monohydrate – 8.7 mg. Sodium Citrate, Dihydrate – 32.5 mg. Dextrose, Anhydrous – 12 mg in Sterile Water for Injection. The total volume of this syringe is 1 mL. The pH range of this solution is adjusted to 4.5 to 5.5 with sodium citrate or citric acid as needed."
},
{
"NDCCode": "69945-075-11",
"PackageDescription": "1 INJECTION, SOLUTION in 1 CARTON (69945-075-11) ",
"NDC11Code": "69945-0075-11",
"ProductNDC": "69945-075",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Ultra-technekow",
"ProprietaryNameSuffix": "V4",
"NonProprietaryName": "Technetium Tc-99m",
"DosageFormName": "INJECTION, SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20140610",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA017243",
"LabelerName": "Curium US LLC",
"SubstanceName": "TECHNETIUM TC-99M SODIUM PERTECHNETATE",
"StrengthNumber": "7.5",
"StrengthUnit": "Ci/1",
"Status": "Active",
"LastUpdate": "2024-10-19",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20140610",
"SamplePackage": "N",
"IndicationAndUsage": "The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.",
"Description": "The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution."
},
{
"NDCCode": "69945-082-00",
"PackageDescription": "1 VIAL, GLASS in 1 CAN (69945-082-00) / 50 mCi in 1 VIAL, GLASS",
"NDC11Code": "69945-0082-00",
"ProductNDC": "69945-082",
"ProductTypeName": "BULK INGREDIENT",
"NonProprietaryName": "Strontium Sr-82 Chloride",
"DosageFormName": "SOLUTION",
"StartMarketingDate": "20180710",
"MarketingCategoryName": "BULK INGREDIENT",
"LabelerName": "Curium US LLC",
"SubstanceName": "STRONTIUM CHLORIDE SR-82",
"StrengthNumber": "50",
"StrengthUnit": "mCi/50mCi",
"Status": "Unfinished",
"LastUpdate": "2026-03-19",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "10-JUL-18"
},
{
"NDCCode": "69945-091-20",
"PackageDescription": "5 VIAL in 1 CELLO PACK (69945-091-20) / 1 INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION in 1 VIAL (69945-091-01) ",
"NDC11Code": "69945-0091-20",
"ProductNDC": "69945-091",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Technescan Hdp",
"NonProprietaryName": "Technetium Tc 99m Oxidronate",
"DosageFormName": "INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20151013",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA018321",
"LabelerName": "Curium US LLC",
"SubstanceName": "OXIDRONATE DISODIUM",
"StrengthNumber": "3.15",
"StrengthUnit": "mg/1",
"Status": "Active",
"LastUpdate": "2025-12-16",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20151013",
"SamplePackage": "N",
"IndicationAndUsage": "Technescan HDP, after radiolabeling with sodium pertechnetate Tc 99m, is indicated for skeletal imaging to demonstrate areas of altered osteogenesis in adult and pediatric patients.",
"Description": "Drug Characteristics. Technescan HDP (kit for the preparation of technetium Tc 99m oxidronate injection) is a radioactive diagnostic drug for intravenous use after radiolabeling with sodium pertechnetate Tc 99m injection. Each vial contains 3.15 mg oxidronate sodium and 0.258 mg, minimum, stannous chloride (SnCl 22H 2O), 0.297 mg, theoretical, stannous chloride (SnCl 22H 2O) with 0.343 mg, maximum, tin chloride [stannous and stannic] dihydrate as SnCl 22H 2O, and the following inactive ingredients: 0.84 mg gentisic acid as a stabilizer and 30 mg sodium chloride. The pH is adjusted with hydrochloric acid and/or sodium hydroxide. The pH of the radiolabeled drug is between 4.0 and 5.5. The vial contains a sterile, non-pyrogenic, lyophilized powder packaged under nitrogen. The chemical structure of oxidronate sodium is. The structure of the technetium Tc 99m oxidronate complex is unknown."
},
{
"NDCCode": "69945-091-40",
"PackageDescription": "30 VIAL in 1 CARTON (69945-091-40) / 1 INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION in 1 VIAL (69945-091-01) ",
"NDC11Code": "69945-0091-40",
"ProductNDC": "69945-091",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Technescan Hdp",
"NonProprietaryName": "Technetium Tc 99m Oxidronate",
"DosageFormName": "INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20151013",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA018321",
"LabelerName": "Curium US LLC",
"SubstanceName": "OXIDRONATE DISODIUM",
"StrengthNumber": "3.15",
"StrengthUnit": "mg/1",
"Status": "Active",
"LastUpdate": "2025-12-16",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20151013",
"SamplePackage": "N",
"IndicationAndUsage": "Technescan HDP, after radiolabeling with sodium pertechnetate Tc 99m, is indicated for skeletal imaging to demonstrate areas of altered osteogenesis in adult and pediatric patients.",
"Description": "Drug Characteristics. Technescan HDP (kit for the preparation of technetium Tc 99m oxidronate injection) is a radioactive diagnostic drug for intravenous use after radiolabeling with sodium pertechnetate Tc 99m injection. Each vial contains 3.15 mg oxidronate sodium and 0.258 mg, minimum, stannous chloride (SnCl 22H 2O), 0.297 mg, theoretical, stannous chloride (SnCl 22H 2O) with 0.343 mg, maximum, tin chloride [stannous and stannic] dihydrate as SnCl 22H 2O, and the following inactive ingredients: 0.84 mg gentisic acid as a stabilizer and 30 mg sodium chloride. The pH is adjusted with hydrochloric acid and/or sodium hydroxide. The pH of the radiolabeled drug is between 4.0 and 5.5. The vial contains a sterile, non-pyrogenic, lyophilized powder packaged under nitrogen. The chemical structure of oxidronate sodium is. The structure of the technetium Tc 99m oxidronate complex is unknown."
},
{
"NDCCode": "69945-092-20",
"PackageDescription": "5 VIAL in 1 CELLO PACK (69945-092-20) > 10 mL in 1 VIAL",
"NDC11Code": "69945-0092-20",
"ProductNDC": "69945-092",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Technetium Tc 99m Sestamibi",
"NonProprietaryName": "Technetium Tc 99m Sestamibi",
"DosageFormName": "INJECTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20111031",
"MarketingCategoryName": "ANDA",
"ApplicationNumber": "ANDA078098",
"LabelerName": "Curium US LLC",
"SubstanceName": "TETRAKIS(2-METHOXYISOBUTYLISOCYANIDE)COPPER(I) TETRAFLUOROBORATE",
"StrengthNumber": "1",
"StrengthUnit": "mg/mL",
"Status": "Active",
"LastUpdate": "2022-06-01",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20111031",
"SamplePackage": "N",
"IndicationAndUsage": "Myocardial Imaging: Kit for the Preparation of Technetium Tc99m Sestamibi Injection is a myocardial perfusion agent that is indicated for detecting coronary artery disease by localizing myocardial ischemia (reversible defects) and infarction (non-reversible defects), in evaluating myocardial function and developing information for use in patient management decisions. Technetium Tc99m Sestamibi evaluation of myocardial ischemia can be accomplished with rest and cardiovascular stress techniques (e.g., exercise or pharmacologic stress in accordance with the pharmacologic stress agent's labeling). It is usually not possible to determine the age of a myocardial infarction or to differentiate a recent myocardial infarction from ischemia. Breast Imaging: Kit for the Preparation of Technetium Tc99m Sestamibi Injection is indicated for planar imaging as a second line diagnostic drug after mammography to assist in the evaluation of breast lesions in patients with an abnormal mammogram or a palpable breast mass. Kit for the Preparation of Technetium Tc99m Sestamibi Injection is not indicated for breast cancer screening, to confirm the presence or absence of malignancy, and it is not an alternative to biopsy.",
"Description": "Each 10 mL vial contains a sterile, non-pyrogenic, lyophilized mixture of: 1 Tetrakis (2-methoxy isobutyl isonitrile) Copper (I) tetrafluoroborate – 1 mg, 2 Sodium Citrate Dihydrate - 2.6 mg, 3 L-Cysteine Hydrochloride Monohydrate – 1 mg, 4 Mannitol - 20 mg, 5 Stannous Chloride, Dihydrate, minimum (SnCl22H2O) - 0.025 mg, 6 Stannous Chloride, Dihydrate (SnCl22H2O) - 0.075 mg, 7 Tin Chloride (stannous and stannic) Dihydrate, maximum (as SnCl22H2O) - 0.086 mg."
},
{
"NDCCode": "69945-092-40",
"PackageDescription": "30 VIAL in 1 CARTON (69945-092-40) > 10 mL in 1 VIAL",
"NDC11Code": "69945-0092-40",
"ProductNDC": "69945-092",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Technetium Tc 99m Sestamibi",
"NonProprietaryName": "Technetium Tc 99m Sestamibi",
"DosageFormName": "INJECTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20111031",
"MarketingCategoryName": "ANDA",
"ApplicationNumber": "ANDA078098",
"LabelerName": "Curium US LLC",
"SubstanceName": "TETRAKIS(2-METHOXYISOBUTYLISOCYANIDE)COPPER(I) TETRAFLUOROBORATE",
"StrengthNumber": "1",
"StrengthUnit": "mg/mL",
"Status": "Active",
"LastUpdate": "2022-06-01",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20111031",
"SamplePackage": "N",
"IndicationAndUsage": "Myocardial Imaging: Kit for the Preparation of Technetium Tc99m Sestamibi Injection is a myocardial perfusion agent that is indicated for detecting coronary artery disease by localizing myocardial ischemia (reversible defects) and infarction (non-reversible defects), in evaluating myocardial function and developing information for use in patient management decisions. Technetium Tc99m Sestamibi evaluation of myocardial ischemia can be accomplished with rest and cardiovascular stress techniques (e.g., exercise or pharmacologic stress in accordance with the pharmacologic stress agent's labeling). It is usually not possible to determine the age of a myocardial infarction or to differentiate a recent myocardial infarction from ischemia. Breast Imaging: Kit for the Preparation of Technetium Tc99m Sestamibi Injection is indicated for planar imaging as a second line diagnostic drug after mammography to assist in the evaluation of breast lesions in patients with an abnormal mammogram or a palpable breast mass. Kit for the Preparation of Technetium Tc99m Sestamibi Injection is not indicated for breast cancer screening, to confirm the presence or absence of malignancy, and it is not an alternative to biopsy.",
"Description": "Each 10 mL vial contains a sterile, non-pyrogenic, lyophilized mixture of: 1 Tetrakis (2-methoxy isobutyl isonitrile) Copper (I) tetrafluoroborate – 1 mg, 2 Sodium Citrate Dihydrate - 2.6 mg, 3 L-Cysteine Hydrochloride Monohydrate – 1 mg, 4 Mannitol - 20 mg, 5 Stannous Chloride, Dihydrate, minimum (SnCl22H2O) - 0.025 mg, 6 Stannous Chloride, Dihydrate (SnCl22H2O) - 0.075 mg, 7 Tin Chloride (stannous and stannic) Dihydrate, maximum (as SnCl22H2O) - 0.086 mg."
},
{
"NDCCode": "69945-094-20",
"PackageDescription": "5 VIAL in 1 CELLO PACK (69945-094-20) / 10 mL in 1 VIAL (69945-094-01) ",
"NDC11Code": "69945-0094-20",
"ProductNDC": "69945-094",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Technescan Pyp",
"NonProprietaryName": "Technetium Tc 99m Pyrophosphate",
"DosageFormName": "INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "20151014",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA017538",
"LabelerName": "Curium US LLC",
"SubstanceName": "SODIUM PYROPHOSPHATE; STANNOUS CHLORIDE",
"StrengthNumber": "11.9; 3.2",
"StrengthUnit": "mg/10mL; mg/10mL",
"Status": "Active",
"LastUpdate": "2025-12-16",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "20151014",
"SamplePackage": "N",
"IndicationAndUsage": "Technescan PYP, after radiolabeling with sodium pertechnetate Tc 99m, is indicated for: Skeletal imaging to demonstrate areas of altered osteogenesis in adults Cardiac imaging as an adjunct in the diagnosis of acute myocardial infarction in adults (See WARNINGS). Technescan PYP, in conjunction with sodium pertechnetate Tc 99m injection for red blood cell (RBC) labeling, is indicated for gated cardiac blood pool imaging and for the detection of gastrointestinal bleeding sites in adults.",
"Description": "Drug Characteristics Technescan PYP (kit for the preparation of technetium Tc 99m pyrophosphate injection) is a radioactive diagnostic drug for intravenous use after radiolabeling with sodium pertechnetate Tc 99m injection or after reconstitution with 0.9% sodium chloride injection in conjunction with sodium pertechnetate Tc 99m injection. Each vial contains 11.9 mg sodium pyrophosphate, 3.2 mg (minimum) stannous chloride (SnCl 22H 2O), and 4.4 mg (maximum) total tin expressed as stannous chloride (SnCl 22H 2O). Prior to lyophilization, the pH is adjusted with hydrochloric acid. The pH of the reconstituted drug is between 4.5 and 7.5. No bacteriostatic preservative is present. The vial contains a sterile, non-pyrogenic, lyophilized powder packaged under nitrogen. The precise structures of the stannous-pyrophosphate and technetium Tc 99m pyrophosphate complexes are not known."
},
{
"NDCCode": "69945-096-20",
"PackageDescription": "5 VIAL in 1 CELLO PACK (69945-096-20) / 1 INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION in 1 VIAL",
"NDC11Code": "69945-0096-20",
"ProductNDC": "69945-096",
"ProductTypeName": "HUMAN PRESCRIPTION DRUG",
"ProprietaryName": "Technescan Mag3",
"NonProprietaryName": "Technescan Tc 99m Mertiatide",
"DosageFormName": "INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION",
"RouteName": "INTRAVENOUS",
"StartMarketingDate": "19900615",
"MarketingCategoryName": "NDA",
"ApplicationNumber": "NDA019882",
"LabelerName": "Curium US LLC",
"SubstanceName": "BETIATIDE",
"StrengthNumber": "1",
"StrengthUnit": "mg/1",
"Status": "Active",
"LastUpdate": "2026-01-08",
"PackageNdcExcludeFlag": "N",
"ProductNdcExcludeFlag": "N",
"ListingRecordCertifiedThrough": "20271231",
"StartMarketingDatePackage": "19900615",
"SamplePackage": "N",
"IndicationAndUsage": "Technetium Tc 99m mertiatide is a renal imaging agent for use in the diagnosis of congenital and acquired abnormalities, renal failure, urinary tract obstruction, and calculi in adults and pediatric patients. (See Pediatric Use.) It is a diagnostic aid in providing renal function, split function, renal angiograms, and renogram curves for whole kidney and renal cortex.",
"Description": "Technescan MAG3 is a kit for the preparation of technetium Tc 99m mertiatide, a diagnostic radiopharmaceutical. It is supplied as a sterile, nonpyrogenic, lyophilized powder. Each vial contains betiatide (N-[N-[N-[(benzoylthio) acetyl]glycyl]glycyl]-glycine). After reconstitution with sterile sodium pertechnetate Tc 99m injection, the technetium Tc 99m mertiatide (disodium[N-[N-[N-(mercaptoacetyl) glycyl]glycyl] glycinato (2-) - N,N′,N″,S′]oxotechnetate (2-)) which is formed is suitable for intravenous administration. Each 10 milliliter vial contains 1 milligram betiatide, 0.05 milligram (minimum) stannous chloride dihydrate (SnCl 22H 2O) and 0.2 milligram (maximum) total tin expressed as stannous chloride dihydrate (SnCl 22H 2O), 40 milligrams sodium tartrate dihydrate (Na 2C 4H 2O 62H 2O), and 20 milligrams lactose monohydrate. Prior to lyophilization, sodium hydroxide or hydrochloric acid may be added for pH adjustment. The pH of the reconstituted drug is between 5.0 and 6.0. No bacteriostatic preservative is present. The contents are sealed under argon. Betiatide is light sensitive and must be protected from light. Betiatide and technetium Tc 99m mertiatide have the following structural formulas:."
}
]
}
<?xml version="1.0" encoding="utf-8"?>
<NDCList>
<NDC>
<NDCCode>69945-894-14</NDCCode>
<PackageDescription>1 INJECTION, SOLUTION in 1 CARTON (69945-894-14) </PackageDescription>
<NDC11Code>69945-0894-14</NDC11Code>
<ProductNDC>69945-894</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Ultra-technekow</ProprietaryName>
<ProprietaryNameSuffix>Dte</ProprietaryNameSuffix>
<NonProprietaryName>Technetium Tc-99m</NonProprietaryName>
<DosageFormName>INJECTION, SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20151207</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA017243</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>TECHNETIUM TC-99M SODIUM PERTECHNETATE</SubstanceName>
<StrengthNumber>16</StrengthNumber>
<StrengthUnit>Ci/1</StrengthUnit>
<Status>Deprecated</Status>
<LastUpdate>2022-01-04</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20211231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20151207</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
</NDC>
<NDC>
<NDCCode>69945-160-14</NDCCode>
<PackageDescription>1 INJECTION, SOLUTION in 1 CARTON (69945-160-14) </PackageDescription>
<NDC11Code>69945-0160-14</NDC11Code>
<ProductNDC>69945-160</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Ultra-technekow</ProprietaryName>
<ProprietaryNameSuffix>V4</ProprietaryNameSuffix>
<NonProprietaryName>Technetium Tc-99m</NonProprietaryName>
<DosageFormName>INJECTION, SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20140610</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA017243</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>TECHNETIUM TC-99M SODIUM PERTECHNETATE</SubstanceName>
<StrengthNumber>16</StrengthNumber>
<StrengthUnit>Ci/1</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2024-10-19</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20140610</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.</IndicationAndUsage>
<Description>The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution.</Description>
</NDC>
<NDC>
<NDCCode>69945-140-13</NDCCode>
<PackageDescription>1 INJECTION, SOLUTION in 1 CARTON (69945-140-13) </PackageDescription>
<NDC11Code>69945-0140-13</NDC11Code>
<ProductNDC>69945-140</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Ultra-technekow</ProprietaryName>
<ProprietaryNameSuffix>V4</ProprietaryNameSuffix>
<NonProprietaryName>Technetium Tc-99m</NonProprietaryName>
<DosageFormName>INJECTION, SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20140610</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA017243</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>TECHNETIUM TC-99M SODIUM PERTECHNETATE</SubstanceName>
<StrengthNumber>14</StrengthNumber>
<StrengthUnit>Ci/1</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2024-10-19</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20140610</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.</IndicationAndUsage>
<Description>The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution.</Description>
</NDC>
<NDC>
<NDCCode>69945-893-13</NDCCode>
<PackageDescription>1 INJECTION, SOLUTION in 1 CARTON (69945-893-13) </PackageDescription>
<NDC11Code>69945-0893-13</NDC11Code>
<ProductNDC>69945-893</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Ultra-technekow</ProprietaryName>
<ProprietaryNameSuffix>Dte</ProprietaryNameSuffix>
<NonProprietaryName>Technetium Tc-99m</NonProprietaryName>
<DosageFormName>INJECTION, SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20151207</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA017243</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>TECHNETIUM TC-99M SODIUM PERTECHNETATE</SubstanceName>
<StrengthNumber>14</StrengthNumber>
<StrengthUnit>Ci/1</StrengthUnit>
<Status>Deprecated</Status>
<LastUpdate>2022-01-04</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20211231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20151207</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
</NDC>
<NDC>
<NDCCode>45865-894-49</NDCCode>
<PackageDescription>100 TABLET, FILM COATED in 1 BOTTLE (45865-894-49) </PackageDescription>
<NDC11Code>45865-0894-49</NDC11Code>
<ProductNDC>45865-894</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Rosuvastatin Calcium</ProprietaryName>
<NonProprietaryName>Rosuvastatin Calcium</NonProprietaryName>
<DosageFormName>TABLET, FILM COATED</DosageFormName>
<RouteName>ORAL</RouteName>
<StartMarketingDate>20161031</StartMarketingDate>
<MarketingCategoryName>ANDA</MarketingCategoryName>
<ApplicationNumber>ANDA206434</ApplicationNumber>
<LabelerName>medsource pharmaceuticals</LabelerName>
<SubstanceName>ROSUVASTATIN CALCIUM</SubstanceName>
<StrengthNumber>40</StrengthNumber>
<StrengthUnit>mg/1</StrengthUnit>
<Pharm_Classes>HMG-CoA Reductase Inhibitor [EPC],Hydroxymethylglutaryl-CoA Reductase Inhibitors [MoA]</Pharm_Classes>
<Status>Deprecated</Status>
<LastUpdate>2020-01-01</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20191231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20180601</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>Pediatric use information for patients 7 to 17 years of age is approved for AstraZeneca’s CRESTOR (rosuvastatin calcium) tablets. However, due to AstraZeneca’s marketing exclusivity rights, this drug product is not labeled with that pediatric information.</IndicationAndUsage>
<Description>Rosuvastatin calcium is a synthetic lipid-lowering agent for oral administration. The chemical name for rosuvastatin calcium is bis[(E)-7-[4-(4-fluorophenyl)-6-isopropyl-2-[methyl(methylsulfonyl)amino] pyrimidin-5-yl](3R,5S)-3,5-dihydroxyhept-6-enoic acid] calcium salt with the following structural formula. The empirical formula for rosuvastatin calcium is (C 22H 27FN 3O 6S) 2Ca and the molecular weight is 1001.14. Rosuvastatin calcium is a white amorphous powder that is sparingly soluble in water and methanol, and slightly soluble in ethanol. Rosuvastatin calcium is a hydrophilic compound with a partition coefficient (octanol/water) of 0.13 at pH of 7.0. Rosuvastatin calcium tablets for oral administration contain 5, 10, 20, or 40 mg of rosuvastatin and the following inactive ingredients: For 5 mg: Each film coated tablet contains: microcrystalline cellulose, lactose monohydrate, anhydrous lactose, crospovidone, magnesium oxide, magnesium stearate, hypromellose, triacetin, titanium dioxide, and ferric oxide yellow. For 10, 20 and 40 mg: Each film coated tablet contains: microcrystalline cellulose, lactose monohydrate, anhydrous lactose, crospovidone, magnesium oxide, magnesium stearate, hypromellose, triacetin, titanium dioxide, FD & C yellow No. 6, FD & C red No. 40, and FD & C blue No.1.</Description>
</NDC>
<NDC>
<NDCCode>58160-894-15</NDCCode>
<PackageDescription>1 KIT in 1 CARTON (58160-894-15) * .5 mL in 1 VIAL (58160-719-03) * .5 mL in 1 SYRINGE (58160-749-07) </PackageDescription>
<NDC11Code>58160-0894-15</NDC11Code>
<ProductNDC>58160-894</ProductNDC>
<ProductTypeName>VACCINE</ProductTypeName>
<ProprietaryName>Arexvy</ProprietaryName>
<NonProprietaryName>Respiratory Syncytial Virus Vaccine Recombinant, Adjuvanted</NonProprietaryName>
<DosageFormName>KIT</DosageFormName>
<StartMarketingDate>20260430</StartMarketingDate>
<MarketingCategoryName>BLA</MarketingCategoryName>
<ApplicationNumber>BLA125775</ApplicationNumber>
<LabelerName>GlaxoSmithKline Biologicals SA</LabelerName>
<Status>Active</Status>
<LastUpdate>2026-08-11</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20260430</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>AREXVY is a vaccine indicated for active immunization for the prevention of lower respiratory tract disease (LRTD) caused by respiratory syncytial virus (RSV) in: 1 individuals 60 years of age and older;, 2 individuals 18 through 59 years of age who are at increased risk for LRTD caused by RSV.</IndicationAndUsage>
<Description>AREXVY (Respiratory Syncytial Virus Vaccine, Adjuvanted) is a sterile injectable suspension for intramuscular use. The vaccine is supplied as a vial of lyophilized recombinant respiratory syncytial virus glycoprotein F stabilized in pre‑fusion conformation (RSVPreF3) as the antigen component, which must be reconstituted at the time of use with the accompanying vial or prefilled syringe of AS01E adjuvant as the Adjuvant Suspension Component. The RSVPreF3 antigen is expressed by culturing genetically engineered Chinese Hamster Ovary cells in media containing no antibiotics or animal‑derived proteins. The RSVPreF3 protein is purified by several chromatographic and filtration steps, formulated with excipients, filled into vials, and lyophilized. The AS01E adjuvant is composed of 3‑O‑desacyl‑4’‑monophosphoryl lipid A (MPL) from Salmonella minnesota and QS‑21, a saponin purified from plant extract Quillaja saponaria Molina, combined in a liposomal formulation. The liposomes are composed of dioleoyl phosphatidylcholine (DOPC) and cholesterol in a phosphate‑buffered saline solution containing disodium phosphate anhydrous, potassium dihydrogen phosphate, sodium chloride, and water for injection. After reconstitution of the vial and vial presentation, each 0.5 mL dose is formulated to contain 120 mcg of the recombinant RSVPreF3 antigen, 25 mcg of MPL, and 25 mcg of QS‑21. Each dose also contains 14.7 mg of Trehalose, 4.4 mg of sodium chloride, 0.83 mg of potassium dihydrogen phosphate, 0.26 mg of dipotassium phosphate, 0.18 mg of polysorbate 80, 0.15 mg of disodium phosphate anhydrous, 0.5 mg of DOPC, and 0.125 mg of cholesterol. After reconstitution of the vial and prefilled syringe presentation, each dose (approximately 0.5 mL) is formulated to contain 120 mcg of the recombinant RSVPreF3 antigen, 25 mcg of MPL, and 25 mcg of QS‑21. Each dose also contains 16.3 mg of Trehalose, 4.4 mg of sodium chloride, 0.87 mg of potassium dihydrogen phosphate, 0.29 mg of dipotassium phosphate, 0.20 mg of polysorbate 80, 0.15 mg of disodium phosphate anhydrous, 0.5 mg of DOPC, and 0.125 mg of cholesterol. AREXVY contains no preservative. Each dose may also contain residual amounts of host cell proteins (≤2.0%) and DNA (≤0.80 ng/mg) from the manufacturing process. The stopper of the vial containing Lyophilized Antigen Component or Adjuvant Suspension Component and the tip cap and plunger stopper of the prefilled syringe containing Adjuvant Suspension Component are not made with natural rubber latex.</Description>
</NDC>
<NDC>
<NDCCode>62135-894-90</NDCCode>
<PackageDescription>90 CAPSULE in 1 BOTTLE (62135-894-90) </PackageDescription>
<NDC11Code>62135-0894-90</NDC11Code>
<ProductNDC>62135-894</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Fenofibrate</ProprietaryName>
<NonProprietaryName>Fenofibrate</NonProprietaryName>
<DosageFormName>CAPSULE</DosageFormName>
<RouteName>ORAL</RouteName>
<StartMarketingDate>20240131</StartMarketingDate>
<MarketingCategoryName>ANDA</MarketingCategoryName>
<ApplicationNumber>ANDA211407</ApplicationNumber>
<LabelerName>Chartwell RX, LLC.</LabelerName>
<SubstanceName>FENOFIBRATE</SubstanceName>
<StrengthNumber>134</StrengthNumber>
<StrengthUnit>mg/1</StrengthUnit>
<Pharm_Classes>Peroxisome Proliferator Receptor alpha Agonist [EPC]</Pharm_Classes>
<Status>Active</Status>
<LastUpdate>2025-12-16</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20261231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20240912</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>Treatment of Hypercholesterolemia. Fenofibrate capsules are indicated as adjunctive therapy to diet for the reduction of LDL-C, Total-C, Triglycerides and apo B in adult patients with primary hypercholesterolemia or mixed dyslipidemia (Fredrickson Types IIa and IIb). Lipid-altering agents should be used in addition to a diet restricted in saturated fat and cholesterol when response to diet and non-pharmacological interventions alone has been inadequate (see National Cholesterol Education Program [NCEP] Treatment Guidelines, below). Treatment of Hypertriglyceridemia. Fenofibrate capsules are also indicated as adjunctive therapy to diet for treatment of adult patients with hypertriglyceridemia (Fredrickson Types IV and V hyperlipidemia). Improving glycemic control in diabetic patients showing fasting chylomicronemia will usually reduce fasting triglycerides and eliminate chylomicronemia thereby obviating the need for pharmacologic intervention. Markedly elevated levels of serum triglycerides (e.g. > 2,000 mg/dL) may increase the risk of developing pancreatitis. The effect of fenofibrate therapy on reducing this risk has not been adequately studied. Drug therapy is not indicated for patients with Type I hyperlipoproteinemia, who have elevations of chylomicrons and plasma triglycerides, but who have normal levels of very low density lipoprotein (VLDL). Inspection of plasma refrigerated for 14 hours is helpful in distinguishing Types I, IV and V hyperlipoproteinemia 2. The initial treatment for dyslipidemia is dietary therapy specific for the type of lipoprotein abnormality. Excess body weight and excess alcoholic intake may be important factors in hypertriglyceridemia and should be addressed prior to any drug therapy. Physical exercise can be an important ancillary measure. Diseases contributory to hyperlipidemia, such as hypothyroidism or diabetes mellitus should be looked for and adequately treated. Estrogen therapy, like thiazide diuretics and beta-blockers, is sometimes associated with massive rises in plasma triglycerides, especially in subjects with familial hypertriglyceridemia. In such cases, discontinuation of the specific etiologic agent may obviate the need for specific drug therapy of hypertriglyceridemia. The use of drugs should be considered only when reasonable attempts have been made to obtain satisfactory results with non-drug methods. If the decision is made to use drugs, the patient should be instructed that this does not reduce the importance of adhering to diet (see WARNINGSand PRECAUTIONS). Fredrickson Classification of Hyperlipoproteinemias. C = cholesterol TG = triglycerides. LDL = low density lipoprotein. VLDL = very low density lipoprotein. IDL = intermediate density lipoprotein. The NCEP Treatment Guidelines. a Coronary heart disease or peripheral vascular disease (including symptomatic carotid artery disease). b Other risk factors for coronary heart disease (CHD) include: age (males: ≥ 4 5 years; females: ≥ 55 years or premature menopause without estrogen replacement therapy); family history of premature CHD; current cigarette smoking; hypertension; confirmed HDL- C <35 mg/dL (<0.91mmol/L); and diabetes mellitus. Subtract 1 risk factor if HDL-C is ≥ 60 mg/dL (≥1.6 mmol/L). c In CHD patients with LDL-C levels 100 to 129 mg/dL, the physician should exercise clinical judgment in deciding whether to initiate drug treatment.</IndicationAndUsage>
<Description>Fenofibrate USP, (micronized) is a lipid regulating agent available as capsules for oral administration. Each capsule contains 67 mg, 134 mg or 200 mg of micronized fenofibrate. The chemical name for fenofibrate is 2-[4-(4-chlorobenzoyl) phenoxy]-2-methyl-propanoic acid, 1- methylethyl ester with the following structural formula. The empirical formula is C 20H 21O 4Cl and the molecular weight is 360.83; fenofibrate is insoluble in water. The melting point is 79-82°C. Fenofibrate is a white solid which is stable under ordinary conditions. Inactive Ingredients:The inactive ingredients in fenofibrate capsules include lactose monohydrate, crospovidone, pregelatinized starch, povidone, sodium lauryl sulfate and magnesium stearate. The capsule shells contain gelatin, titanium dioxide, FD&C Blue # 1, and FD#C Red #3. Additionally, the capsule imprint ink contains shellac, dehydrated alcohol, isopropyl alcohol, butyl alcohol, propylene glycol, strong ammonium solution, black iron oxide, potassium hydroxide and purified water.</Description>
</NDC>
<NDC>
<NDCCode>68180-894-73</NDCCode>
<PackageDescription>3 POUCH in 1 CARTON (68180-894-73) / 1 BLISTER PACK in 1 POUCH / 1 KIT in 1 BLISTER PACK</PackageDescription>
<NDC11Code>68180-0894-73</NDC11Code>
<ProductNDC>68180-894</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Drospirenone, Ethinyl Estradiol And Levomefolate Calcium And Levomefolate Calcium</ProprietaryName>
<NonProprietaryName>Drospirenone, Ethinyl Estradiol And Levomefolate Calcium And Levomefolate Calcium</NonProprietaryName>
<DosageFormName>KIT</DosageFormName>
<StartMarketingDate>20180822</StartMarketingDate>
<MarketingCategoryName>ANDA</MarketingCategoryName>
<ApplicationNumber>ANDA205947</ApplicationNumber>
<LabelerName>Lupin Pharmaceuticals, Inc.</LabelerName>
<Status>Active</Status>
<LastUpdate>2025-12-16</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20261231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20180822</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>Drospirenone, ethinyl estradiol and levomefolate calcium tablet and levomefolate calcium tablet is a combination of drospirenone, a progestin and ethinyl estradiol, an estrogen containing a folate, indicated for use by females of reproductive potential to: 1 Prevent pregnancy. (1.1), 2 Treat symptoms of premenstrual dysphoric disorder (PMDD) for females of reproductive potential who choose to use an oral contraceptive for contraception. (1.2), 3 Treat moderate acne for females of reproductive potential at least 14 years old only if the patient desires an oral contraceptive for birth control. (1.3), 4 Raise folate levels in females of reproductive potential who choose to use an oral contraceptive for contraception. (1.4).</IndicationAndUsage>
<Description>Drospirenone, ethinyl estradiol and levomefolate calcium tablets and levomefolate calcium tablets provide an oral contraceptive regimen consisting of 28 film-coated tablets that contain the active ingredients specified for each tablet below: 1 24 pink tablets each containing 3 mg DRSP, 0.02 mg EE, and 0.451 mg levomefolate calcium, 2 4 light orange tablets each containing 0.451 mg levomefolate calcium.</Description>
</NDC>
<NDC>
<NDCCode>69097-894-02</NDCCode>
<PackageDescription>30 CAPSULE in 1 BOTTLE, PLASTIC (69097-894-02) </PackageDescription>
<NDC11Code>69097-0894-02</NDC11Code>
<ProductNDC>69097-894</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Fenofibrate</ProprietaryName>
<NonProprietaryName>Fenofibrate</NonProprietaryName>
<DosageFormName>CAPSULE</DosageFormName>
<RouteName>ORAL</RouteName>
<StartMarketingDate>20170330</StartMarketingDate>
<MarketingCategoryName>ANDA</MarketingCategoryName>
<ApplicationNumber>ANDA207378</ApplicationNumber>
<LabelerName>Cipla USA Inc.,</LabelerName>
<SubstanceName>FENOFIBRATE</SubstanceName>
<StrengthNumber>67</StrengthNumber>
<StrengthUnit>mg/1</StrengthUnit>
<Pharm_Classes>Peroxisome Proliferator Receptor alpha Agonist [EPC]</Pharm_Classes>
<Status>Active</Status>
<LastUpdate>2023-01-24</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20170330</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>Treatment of Hypercholesterolemia. Fenofibrate capsules, USP are indicated as adjunctive therapy to diet for the reduction of LDLC, total-C, Triglycerides and apo B in adult patients with primary hypercholesterolemia or mixed dyslipidemia (Fredrickson Types IIa and IIb). Lipid altering agents should be used in addition to a diet restricted in saturated fat and cholesterol when response to diet and non-pharmacological interventions alone has been inadequate (see National Cholesterol Education Program [NCEP] Treatment Guidelines, below). Treatment of Hypertriglyceridemia. Fenofibrate capsules, USP are also indicated as adjunctive therapy to diet for treatment of adult patients with hypertriglyceridemia (Fredrickson Types IV and V hyperlipidemia). Improving glycemic control in diabetic patients showing fasting chylomicronemia will usually reduce fasting triglycerides and eliminate chylomicronemia thereby obviating the need for pharmacologic intervention. Markedly elevated levels of serum triglycerides (e.g. > 2,000 mg/dL) may increase the risk of developing pancreatitis. The effect of fenofibrate therapy on reducing this risk has not been adequately studied. Drug therapy is not indicated for patients with Type I hyperlipoproteinemia, who have elevations of chylomicrons and plasma triglycerides, but who have normal levels of very low density lipoprotein (VLDL). Inspection of plasma refrigerated for 14 hours is helpful in distinguishing Types I, IV and V hyperlipoproteinemia2. The initial treatment for dyslipidemia is dietary therapy specific for the type of lipoprotein abnormality. Excess body weight and excess alcoholic intake may be important factors in hypertriglyceridemia and should be addressed prior to any drug therapy. Physical exercise can be an important ancillary measure. Diseases contributory to hyperlipidemia, such as hypothyroidism or diabetes mellitus should be looked for and adequately treated. Estrogen therapy, like thiazide diuretics and beta-blockers, is sometimes associated with massive rises in plasma triglycerides, especially in subjects with familial hypertriglyceridemia. In such cases, discontinuation of the specific etiologic agent may obviate the need for specific drug therapy of hypertriglyceridemia. The use of drugs should be considered only when reasonable attempts have been made to obtain satisfactory results with non-drug methods. If the decision is made to use drugs, the patient should be instructed that this does not reduce the importance of adhering to diet (See WARNINGS and PRECAUTIONS).</IndicationAndUsage>
<Description>Fenofibrate capsules, USP (micronized) are a lipid regulating agent available as capsules for oral administration. The chemical name for fenofibrate is 2-[4-(4-chlorobenzoyl) phenoxy]-2- methylpropanoic acid, 1-methylethyl ester with the following structural formula. The molecular formula is C20H21O4Cl and the molecular weight is 360.83; fenofibrate is insoluble in water. The melting point is 79° to 82°C. Fenofibrate, USP is a white solid which is stable under ordinary conditions. Each 67 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, FD&C Red No.3, D&C Yellow No.10, titanium dioxide and gelatin. Each 134 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, D&C Red No.28, titanium dioxide and gelatin. Each 200 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, FD&C Red No.40, FD&C Yellow No.6, titanium dioxide and gelatin. The imprinting ink contains shellac, dehydrated alcohol, isopropyl alcohol, butyl alcohol, propylene glycol, strong ammonia solution, black iron oxide, potassium hydroxide and purified water. USP dissolution test is pending.</Description>
</NDC>
<NDC>
<NDCCode>69097-894-07</NDCCode>
<PackageDescription>100 CAPSULE in 1 BOTTLE, PLASTIC (69097-894-07) </PackageDescription>
<NDC11Code>69097-0894-07</NDC11Code>
<ProductNDC>69097-894</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Fenofibrate</ProprietaryName>
<NonProprietaryName>Fenofibrate</NonProprietaryName>
<DosageFormName>CAPSULE</DosageFormName>
<RouteName>ORAL</RouteName>
<StartMarketingDate>20170330</StartMarketingDate>
<MarketingCategoryName>ANDA</MarketingCategoryName>
<ApplicationNumber>ANDA207378</ApplicationNumber>
<LabelerName>Cipla USA Inc.,</LabelerName>
<SubstanceName>FENOFIBRATE</SubstanceName>
<StrengthNumber>67</StrengthNumber>
<StrengthUnit>mg/1</StrengthUnit>
<Pharm_Classes>Peroxisome Proliferator Receptor alpha Agonist [EPC]</Pharm_Classes>
<Status>Active</Status>
<LastUpdate>2023-01-24</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20170330</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>Treatment of Hypercholesterolemia. Fenofibrate capsules, USP are indicated as adjunctive therapy to diet for the reduction of LDLC, total-C, Triglycerides and apo B in adult patients with primary hypercholesterolemia or mixed dyslipidemia (Fredrickson Types IIa and IIb). Lipid altering agents should be used in addition to a diet restricted in saturated fat and cholesterol when response to diet and non-pharmacological interventions alone has been inadequate (see National Cholesterol Education Program [NCEP] Treatment Guidelines, below). Treatment of Hypertriglyceridemia. Fenofibrate capsules, USP are also indicated as adjunctive therapy to diet for treatment of adult patients with hypertriglyceridemia (Fredrickson Types IV and V hyperlipidemia). Improving glycemic control in diabetic patients showing fasting chylomicronemia will usually reduce fasting triglycerides and eliminate chylomicronemia thereby obviating the need for pharmacologic intervention. Markedly elevated levels of serum triglycerides (e.g. > 2,000 mg/dL) may increase the risk of developing pancreatitis. The effect of fenofibrate therapy on reducing this risk has not been adequately studied. Drug therapy is not indicated for patients with Type I hyperlipoproteinemia, who have elevations of chylomicrons and plasma triglycerides, but who have normal levels of very low density lipoprotein (VLDL). Inspection of plasma refrigerated for 14 hours is helpful in distinguishing Types I, IV and V hyperlipoproteinemia2. The initial treatment for dyslipidemia is dietary therapy specific for the type of lipoprotein abnormality. Excess body weight and excess alcoholic intake may be important factors in hypertriglyceridemia and should be addressed prior to any drug therapy. Physical exercise can be an important ancillary measure. Diseases contributory to hyperlipidemia, such as hypothyroidism or diabetes mellitus should be looked for and adequately treated. Estrogen therapy, like thiazide diuretics and beta-blockers, is sometimes associated with massive rises in plasma triglycerides, especially in subjects with familial hypertriglyceridemia. In such cases, discontinuation of the specific etiologic agent may obviate the need for specific drug therapy of hypertriglyceridemia. The use of drugs should be considered only when reasonable attempts have been made to obtain satisfactory results with non-drug methods. If the decision is made to use drugs, the patient should be instructed that this does not reduce the importance of adhering to diet (See WARNINGS and PRECAUTIONS).</IndicationAndUsage>
<Description>Fenofibrate capsules, USP (micronized) are a lipid regulating agent available as capsules for oral administration. The chemical name for fenofibrate is 2-[4-(4-chlorobenzoyl) phenoxy]-2- methylpropanoic acid, 1-methylethyl ester with the following structural formula. The molecular formula is C20H21O4Cl and the molecular weight is 360.83; fenofibrate is insoluble in water. The melting point is 79° to 82°C. Fenofibrate, USP is a white solid which is stable under ordinary conditions. Each 67 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, FD&C Red No.3, D&C Yellow No.10, titanium dioxide and gelatin. Each 134 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, D&C Red No.28, titanium dioxide and gelatin. Each 200 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, FD&C Red No.40, FD&C Yellow No.6, titanium dioxide and gelatin. The imprinting ink contains shellac, dehydrated alcohol, isopropyl alcohol, butyl alcohol, propylene glycol, strong ammonia solution, black iron oxide, potassium hydroxide and purified water. USP dissolution test is pending.</Description>
</NDC>
<NDC>
<NDCCode>69097-894-15</NDCCode>
<PackageDescription>1000 CAPSULE in 1 BOTTLE, PLASTIC (69097-894-15) </PackageDescription>
<NDC11Code>69097-0894-15</NDC11Code>
<ProductNDC>69097-894</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Fenofibrate</ProprietaryName>
<NonProprietaryName>Fenofibrate</NonProprietaryName>
<DosageFormName>CAPSULE</DosageFormName>
<RouteName>ORAL</RouteName>
<StartMarketingDate>20170330</StartMarketingDate>
<MarketingCategoryName>ANDA</MarketingCategoryName>
<ApplicationNumber>ANDA207378</ApplicationNumber>
<LabelerName>Cipla USA Inc.,</LabelerName>
<SubstanceName>FENOFIBRATE</SubstanceName>
<StrengthNumber>67</StrengthNumber>
<StrengthUnit>mg/1</StrengthUnit>
<Pharm_Classes>Peroxisome Proliferator Receptor alpha Agonist [EPC]</Pharm_Classes>
<Status>Active</Status>
<LastUpdate>2023-01-24</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20170330</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>Treatment of Hypercholesterolemia. Fenofibrate capsules, USP are indicated as adjunctive therapy to diet for the reduction of LDLC, total-C, Triglycerides and apo B in adult patients with primary hypercholesterolemia or mixed dyslipidemia (Fredrickson Types IIa and IIb). Lipid altering agents should be used in addition to a diet restricted in saturated fat and cholesterol when response to diet and non-pharmacological interventions alone has been inadequate (see National Cholesterol Education Program [NCEP] Treatment Guidelines, below). Treatment of Hypertriglyceridemia. Fenofibrate capsules, USP are also indicated as adjunctive therapy to diet for treatment of adult patients with hypertriglyceridemia (Fredrickson Types IV and V hyperlipidemia). Improving glycemic control in diabetic patients showing fasting chylomicronemia will usually reduce fasting triglycerides and eliminate chylomicronemia thereby obviating the need for pharmacologic intervention. Markedly elevated levels of serum triglycerides (e.g. > 2,000 mg/dL) may increase the risk of developing pancreatitis. The effect of fenofibrate therapy on reducing this risk has not been adequately studied. Drug therapy is not indicated for patients with Type I hyperlipoproteinemia, who have elevations of chylomicrons and plasma triglycerides, but who have normal levels of very low density lipoprotein (VLDL). Inspection of plasma refrigerated for 14 hours is helpful in distinguishing Types I, IV and V hyperlipoproteinemia2. The initial treatment for dyslipidemia is dietary therapy specific for the type of lipoprotein abnormality. Excess body weight and excess alcoholic intake may be important factors in hypertriglyceridemia and should be addressed prior to any drug therapy. Physical exercise can be an important ancillary measure. Diseases contributory to hyperlipidemia, such as hypothyroidism or diabetes mellitus should be looked for and adequately treated. Estrogen therapy, like thiazide diuretics and beta-blockers, is sometimes associated with massive rises in plasma triglycerides, especially in subjects with familial hypertriglyceridemia. In such cases, discontinuation of the specific etiologic agent may obviate the need for specific drug therapy of hypertriglyceridemia. The use of drugs should be considered only when reasonable attempts have been made to obtain satisfactory results with non-drug methods. If the decision is made to use drugs, the patient should be instructed that this does not reduce the importance of adhering to diet (See WARNINGS and PRECAUTIONS).</IndicationAndUsage>
<Description>Fenofibrate capsules, USP (micronized) are a lipid regulating agent available as capsules for oral administration. The chemical name for fenofibrate is 2-[4-(4-chlorobenzoyl) phenoxy]-2- methylpropanoic acid, 1-methylethyl ester with the following structural formula. The molecular formula is C20H21O4Cl and the molecular weight is 360.83; fenofibrate is insoluble in water. The melting point is 79° to 82°C. Fenofibrate, USP is a white solid which is stable under ordinary conditions. Each 67 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, FD&C Red No.3, D&C Yellow No.10, titanium dioxide and gelatin. Each 134 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, D&C Red No.28, titanium dioxide and gelatin. Each 200 mg fenofibrate capsule contains the following inactive ingredients: lactose monohydrate, crospovidone, povidone, sodium lauryl sulfate, colloidal silicon dioxide, magnesium stearate, FD&C Blue No.1, FD&C Red No.40, FD&C Yellow No.6, titanium dioxide and gelatin. The imprinting ink contains shellac, dehydrated alcohol, isopropyl alcohol, butyl alcohol, propylene glycol, strong ammonia solution, black iron oxide, potassium hydroxide and purified water. USP dissolution test is pending.</Description>
</NDC>
<NDC>
<NDCCode>69945-010-03</NDCCode>
<PackageDescription>1 INJECTION, SOLUTION in 1 CARTON (69945-010-03) </PackageDescription>
<NDC11Code>69945-0010-03</NDC11Code>
<ProductNDC>69945-010</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Ultra-technekow</ProprietaryName>
<ProprietaryNameSuffix>V4</ProprietaryNameSuffix>
<NonProprietaryName>Technetium Tc-99m</NonProprietaryName>
<DosageFormName>INJECTION, SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20140610</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA017243</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>TECHNETIUM TC-99M SODIUM PERTECHNETATE</SubstanceName>
<StrengthNumber>1</StrengthNumber>
<StrengthUnit>Ci/1</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2024-10-19</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20140610</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.</IndicationAndUsage>
<Description>The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution.</Description>
</NDC>
<NDC>
<NDCCode>69945-015-04</NDCCode>
<PackageDescription>1 INJECTION, SOLUTION in 1 CARTON (69945-015-04) </PackageDescription>
<NDC11Code>69945-0015-04</NDC11Code>
<ProductNDC>69945-015</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Ultra-technekow</ProprietaryName>
<ProprietaryNameSuffix>V4</ProprietaryNameSuffix>
<NonProprietaryName>Technetium Tc-99m</NonProprietaryName>
<DosageFormName>INJECTION, SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20140610</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA017243</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>TECHNETIUM TC-99M SODIUM PERTECHNETATE</SubstanceName>
<StrengthNumber>1.5</StrengthNumber>
<StrengthUnit>Ci/1</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2024-10-19</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20140610</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.</IndicationAndUsage>
<Description>The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution.</Description>
</NDC>
<NDC>
<NDCCode>69945-020-05</NDCCode>
<PackageDescription>1 INJECTION, SOLUTION in 1 CARTON (69945-020-05) </PackageDescription>
<NDC11Code>69945-0020-05</NDC11Code>
<ProductNDC>69945-020</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Ultra-technekow</ProprietaryName>
<ProprietaryNameSuffix>V4</ProprietaryNameSuffix>
<NonProprietaryName>Technetium Tc-99m</NonProprietaryName>
<DosageFormName>INJECTION, SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20140610</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA017243</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>TECHNETIUM TC-99M SODIUM PERTECHNETATE</SubstanceName>
<StrengthNumber>2</StrengthNumber>
<StrengthUnit>Ci/1</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2024-10-19</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20140610</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.</IndicationAndUsage>
<Description>The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution.</Description>
</NDC>
<NDC>
<NDCCode>69945-025-06</NDCCode>
<PackageDescription>1 INJECTION, SOLUTION in 1 CARTON (69945-025-06) </PackageDescription>
<NDC11Code>69945-0025-06</NDC11Code>
<ProductNDC>69945-025</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Ultra-technekow</ProprietaryName>
<ProprietaryNameSuffix>V4</ProprietaryNameSuffix>
<NonProprietaryName>Technetium Tc-99m</NonProprietaryName>
<DosageFormName>INJECTION, SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20140610</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA017243</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>TECHNETIUM TC-99M SODIUM PERTECHNETATE</SubstanceName>
<StrengthNumber>2.5</StrengthNumber>
<StrengthUnit>Ci/1</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2024-10-19</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20140610</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.</IndicationAndUsage>
<Description>The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution.</Description>
</NDC>
<NDC>
<NDCCode>69945-030-07</NDCCode>
<PackageDescription>1 INJECTION, SOLUTION in 1 CARTON (69945-030-07) </PackageDescription>
<NDC11Code>69945-0030-07</NDC11Code>
<ProductNDC>69945-030</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Ultra-technekow</ProprietaryName>
<ProprietaryNameSuffix>V4</ProprietaryNameSuffix>
<NonProprietaryName>Technetium Tc-99m</NonProprietaryName>
<DosageFormName>INJECTION, SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20140610</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA017243</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>TECHNETIUM TC-99M SODIUM PERTECHNETATE</SubstanceName>
<StrengthNumber>3</StrengthNumber>
<StrengthUnit>Ci/1</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2024-10-19</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20140610</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.</IndicationAndUsage>
<Description>The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution.</Description>
</NDC>
<NDC>
<NDCCode>69945-035-08</NDCCode>
<PackageDescription>1 INJECTION, SOLUTION in 1 CARTON (69945-035-08) </PackageDescription>
<NDC11Code>69945-0035-08</NDC11Code>
<ProductNDC>69945-035</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Ultra-technekow</ProprietaryName>
<ProprietaryNameSuffix>V4</ProprietaryNameSuffix>
<NonProprietaryName>Technetium Tc-99m</NonProprietaryName>
<DosageFormName>INJECTION, SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20140610</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA017243</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>TECHNETIUM TC-99M SODIUM PERTECHNETATE</SubstanceName>
<StrengthNumber>3.5</StrengthNumber>
<StrengthUnit>Ci/1</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2024-10-19</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20140610</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.</IndicationAndUsage>
<Description>The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution.</Description>
</NDC>
<NDC>
<NDCCode>69945-050-40</NDCCode>
<PackageDescription>1 KIT in 1 BOX (69945-050-40) * 1 mL in 1 VIAL, GLASS * 1 mL in 1 VIAL, GLASS</PackageDescription>
<NDC11Code>69945-0050-40</NDC11Code>
<ProductNDC>69945-050</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Octreoscan</ProprietaryName>
<NonProprietaryName>Indium In -111 Pentetreotide</NonProprietaryName>
<DosageFormName>KIT</DosageFormName>
<StartMarketingDate>20151014</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA020314</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<Status>Active</Status>
<LastUpdate>2022-02-23</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20151014</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>Octreoscan, after radiolabeling, is an agent for the scintigraphic localization of primary and metastatic neuroendocrine tumors bearing somatostatin receptors.</IndicationAndUsage>
<Description>Octreoscan is a kit for the preparation of Indium In 111 Pentetreotide Injection, a radioactive diagnostic agent. It is a kit consisting of two components. 1) A 10-mL Octreoscan Reaction Vial which contains a lyophilized mixture of: (i) 10 mcg pentetreotide [N-(diethylenetriamine-N,N,N′,N″-tetraacetic acid-N″-acetyl)-D-phenylalanyl-L-hemicystyl-L-phenylalanyl-D-tryptophyl-L-lysyl-L-threonyl-L-hemicystyl-L-threoninol cyclic (2→7) disulfide], (also known as octreotide DTPA), (ii) 2 mg gentisic acid [2, 5-dihydroxybenzoic acid], (iii) 4.9 mg trisodium citrate, anhydrous, (iv) 0.37 mg citric acid, anhydrous, and (v) 10 mg inositol. Pentetreotide has the following structural formula. Prior to lyophilization, sodium hydroxide or hydrochloric acid may have been added for pH adjustment. The vial contents are sterile and nonpyrogenic. No bacteriostatic preservative is present. 2) A 10-mL vial of Indium In 111 Chloride Solution, which contains: 1.1 mL or 111 MBq/mL (3 mCi/mL) indium In 111 chloride in 0.02N HCl at time of calibration. The vial also contains ferric chloride at a concentration of 3.5 mcg/mL (ferric ion, 1.2 mcg/mL). The vial contents are sterile and nonpyrogenic. No bacteriostatic preservative is present. Indium In 111 Pentetreotide Injection is prepared by combining the two kit components (see INSTRUCTIONS FOR THE PREPARATION OF INDIUM In 111 PENTETREOTIDE INJECTION). Indium In-111 reacts with the diethylenetriaminetetraacetic acid portion of the pentetreotide molecule to form indium In 111 pentetreotide. The pH of the resultant Indium In 111 Pentetreotide Injection is between 3.8 and 4.3. No bacteriostatic preservative is present. The Indium In 111 Pentetreotide Injection is suitable for intravenous administration as is, or it may be diluted to a maximum volume of 3 mL with 0.9% Sodium Chloride Injection, USP, immediately before intravenous administration. In either case, the radiolabeling yield of Indium In 111 Pentetreotide Injection should be determined before administration to the patient. A method recommended for determining the radiolabeling yield is presented at the end of this package insert (see RECOMMENDED METHOD FOR DETERMINATION OF RADIOLABELING YIELD OF INDIUM In 111 PENTETREOTIDE INJECTION).</Description>
</NDC>
<NDC>
<NDCCode>69945-051-09</NDCCode>
<PackageDescription>1 INJECTION, SOLUTION in 1 CARTON (69945-051-09) </PackageDescription>
<NDC11Code>69945-0051-09</NDC11Code>
<ProductNDC>69945-051</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Ultra-technekow</ProprietaryName>
<ProprietaryNameSuffix>V4</ProprietaryNameSuffix>
<NonProprietaryName>Technetium Tc-99m</NonProprietaryName>
<DosageFormName>INJECTION, SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20140610</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA017243</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>TECHNETIUM TC-99M SODIUM PERTECHNETATE</SubstanceName>
<StrengthNumber>5</StrengthNumber>
<StrengthUnit>Ci/1</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2024-10-19</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20140610</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.</IndicationAndUsage>
<Description>The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution.</Description>
</NDC>
<NDC>
<NDCCode>69945-060-10</NDCCode>
<PackageDescription>1 INJECTION, SOLUTION in 1 CARTON (69945-060-10) </PackageDescription>
<NDC11Code>69945-0060-10</NDC11Code>
<ProductNDC>69945-060</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Ultra-technekow</ProprietaryName>
<ProprietaryNameSuffix>V4</ProprietaryNameSuffix>
<NonProprietaryName>Technetium Tc-99m</NonProprietaryName>
<DosageFormName>INJECTION, SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20140610</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA017243</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>TECHNETIUM TC-99M SODIUM PERTECHNETATE</SubstanceName>
<StrengthNumber>6</StrengthNumber>
<StrengthUnit>Ci/1</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2024-10-19</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20140610</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.</IndicationAndUsage>
<Description>The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution.</Description>
</NDC>
<NDC>
<NDCCode>69945-064-01</NDCCode>
<PackageDescription>1 VIAL, SINGLE-USE in 1 CAN (69945-064-01) / 4 mL in 1 VIAL, SINGLE-USE</PackageDescription>
<NDC11Code>69945-0064-01</NDC11Code>
<ProductNDC>69945-064</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Detectnet</ProprietaryName>
<NonProprietaryName>Copper Cu 64 Dotatate</NonProprietaryName>
<DosageFormName>INJECTION, SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20200914</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA213227</ApplicationNumber>
<LabelerName>CURIUM US LLC</LabelerName>
<SubstanceName>COPPER OXODOTREOTIDE CU-64</SubstanceName>
<StrengthNumber>1</StrengthNumber>
<StrengthUnit>mCi/mL</StrengthUnit>
<Pharm_Classes>Positron Emitting Activity [MoA], Radioactive Diagnostic Agent [EPC]</Pharm_Classes>
<Status>Active</Status>
<LastUpdate>2025-02-04</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20200914</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>Detectnet is indicated for use with positron emission tomography (PET) for localization of somatostatin receptor positive neuroendocrine tumors (NETs) in adult patients.</IndicationAndUsage>
</NDC>
<NDC>
<NDCCode>69945-068-20</NDCCode>
<PackageDescription>5 CELLO PACK in 1 BOX (69945-068-20) / 1 KIT in 1 CELLO PACK (69945-068-10) * .6 mL in 1 SYRINGE, GLASS * 1 mL in 1 SYRINGE, GLASS * 9.5 mg in 1 VIAL, GLASS</PackageDescription>
<NDC11Code>69945-0068-20</NDC11Code>
<ProductNDC>69945-068</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Ultratag</ProprietaryName>
<ProprietaryNameSuffix>Rbc</ProprietaryNameSuffix>
<NonProprietaryName>Kit For The Preparation Of Technetium Tc 99m Red Blood Cells</NonProprietaryName>
<DosageFormName>KIT</DosageFormName>
<StartMarketingDate>19910610</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA019981</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<Status>Active</Status>
<LastUpdate>2025-07-04</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>19910610</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>Technetium Tc 99m red blood cells are used for blood pool imaging, including cardiac first pass and gated equilibrium imaging and for detection of sites of gastrointestinal bleeding.</IndicationAndUsage>
<Description>Ultratag RBC (Kit for the Preparation of Technetium Tc 99m Red Blood Cells Injection) is a sterile, nonpyrogenic, diagnostic kit for the in vitro preparation of Technetium Tc 99m Red Blood Cells Injection. Each kit consists of three separate nonradioactive components. 1. A 10 milliliter reaction vial containing. Stannous Chloride, Dihydrate (SnCl 22H 2O) – 50 mcg minimum. Stannous Chloride, Dihydrate (SnCl 22H 2O) – 96 mcg theoretical. Tin Chloride (Stannous and Stannic), Dihydrate (as SnCl 22H 2O) – 105 mcg maximum. Sodium Citrate, Dihydrate – 3.67 mg. Dextrose, Anhydrous – 5.5 mg. Hydrochloric Acid – 0.47 mg. Prior to lyophilization, the pH is adjusted to 7.1 to 7.2 with sodium hydroxide. The contents of the vial are lyophilized and stored under argon. 2. Syringe I contains. Sodium Hypochlorite – 0.6 mg in Sterile Water for Injection. The total volume of this syringe is 0.6 mL. Sodium hydroxide may have been added for pH adjustment. The pH of this solution is 11 to 13. The syringe must be protected from light to prevent degradation of the light-sensitive sodium hypochlorite. 3. Syringe II contains. Citric Acid, Monohydrate – 8.7 mg. Sodium Citrate, Dihydrate – 32.5 mg. Dextrose, Anhydrous – 12 mg in Sterile Water for Injection. The total volume of this syringe is 1 mL. The pH range of this solution is adjusted to 4.5 to 5.5 with sodium citrate or citric acid as needed.</Description>
</NDC>
<NDC>
<NDCCode>69945-075-11</NDCCode>
<PackageDescription>1 INJECTION, SOLUTION in 1 CARTON (69945-075-11) </PackageDescription>
<NDC11Code>69945-0075-11</NDC11Code>
<ProductNDC>69945-075</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Ultra-technekow</ProprietaryName>
<ProprietaryNameSuffix>V4</ProprietaryNameSuffix>
<NonProprietaryName>Technetium Tc-99m</NonProprietaryName>
<DosageFormName>INJECTION, SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20140610</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA017243</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>TECHNETIUM TC-99M SODIUM PERTECHNETATE</SubstanceName>
<StrengthNumber>7.5</StrengthNumber>
<StrengthUnit>Ci/1</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2024-10-19</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20140610</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>The Ultra-Technekow V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTSas an agent for:. Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy). Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTSas an agent for:. Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux.</IndicationAndUsage>
<Description>The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution.</Description>
</NDC>
<NDC>
<NDCCode>69945-082-00</NDCCode>
<PackageDescription>1 VIAL, GLASS in 1 CAN (69945-082-00) / 50 mCi in 1 VIAL, GLASS</PackageDescription>
<NDC11Code>69945-0082-00</NDC11Code>
<ProductNDC>69945-082</ProductNDC>
<ProductTypeName>BULK INGREDIENT</ProductTypeName>
<NonProprietaryName>Strontium Sr-82 Chloride</NonProprietaryName>
<DosageFormName>SOLUTION</DosageFormName>
<StartMarketingDate>20180710</StartMarketingDate>
<MarketingCategoryName>BULK INGREDIENT</MarketingCategoryName>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>STRONTIUM CHLORIDE SR-82</SubstanceName>
<StrengthNumber>50</StrengthNumber>
<StrengthUnit>mCi/50mCi</StrengthUnit>
<Status>Unfinished</Status>
<LastUpdate>2026-03-19</LastUpdate>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>10-JUL-18</StartMarketingDatePackage>
</NDC>
<NDC>
<NDCCode>69945-091-20</NDCCode>
<PackageDescription>5 VIAL in 1 CELLO PACK (69945-091-20) / 1 INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION in 1 VIAL (69945-091-01) </PackageDescription>
<NDC11Code>69945-0091-20</NDC11Code>
<ProductNDC>69945-091</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Technescan Hdp</ProprietaryName>
<NonProprietaryName>Technetium Tc 99m Oxidronate</NonProprietaryName>
<DosageFormName>INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20151013</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA018321</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>OXIDRONATE DISODIUM</SubstanceName>
<StrengthNumber>3.15</StrengthNumber>
<StrengthUnit>mg/1</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2025-12-16</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20151013</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>Technescan HDP, after radiolabeling with sodium pertechnetate Tc 99m, is indicated for skeletal imaging to demonstrate areas of altered osteogenesis in adult and pediatric patients.</IndicationAndUsage>
<Description>Drug Characteristics. Technescan HDP (kit for the preparation of technetium Tc 99m oxidronate injection) is a radioactive diagnostic drug for intravenous use after radiolabeling with sodium pertechnetate Tc 99m injection. Each vial contains 3.15 mg oxidronate sodium and 0.258 mg, minimum, stannous chloride (SnCl 22H 2O), 0.297 mg, theoretical, stannous chloride (SnCl 22H 2O) with 0.343 mg, maximum, tin chloride [stannous and stannic] dihydrate as SnCl 22H 2O, and the following inactive ingredients: 0.84 mg gentisic acid as a stabilizer and 30 mg sodium chloride. The pH is adjusted with hydrochloric acid and/or sodium hydroxide. The pH of the radiolabeled drug is between 4.0 and 5.5. The vial contains a sterile, non-pyrogenic, lyophilized powder packaged under nitrogen. The chemical structure of oxidronate sodium is. The structure of the technetium Tc 99m oxidronate complex is unknown.</Description>
</NDC>
<NDC>
<NDCCode>69945-091-40</NDCCode>
<PackageDescription>30 VIAL in 1 CARTON (69945-091-40) / 1 INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION in 1 VIAL (69945-091-01) </PackageDescription>
<NDC11Code>69945-0091-40</NDC11Code>
<ProductNDC>69945-091</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Technescan Hdp</ProprietaryName>
<NonProprietaryName>Technetium Tc 99m Oxidronate</NonProprietaryName>
<DosageFormName>INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20151013</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA018321</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>OXIDRONATE DISODIUM</SubstanceName>
<StrengthNumber>3.15</StrengthNumber>
<StrengthUnit>mg/1</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2025-12-16</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20151013</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>Technescan HDP, after radiolabeling with sodium pertechnetate Tc 99m, is indicated for skeletal imaging to demonstrate areas of altered osteogenesis in adult and pediatric patients.</IndicationAndUsage>
<Description>Drug Characteristics. Technescan HDP (kit for the preparation of technetium Tc 99m oxidronate injection) is a radioactive diagnostic drug for intravenous use after radiolabeling with sodium pertechnetate Tc 99m injection. Each vial contains 3.15 mg oxidronate sodium and 0.258 mg, minimum, stannous chloride (SnCl 22H 2O), 0.297 mg, theoretical, stannous chloride (SnCl 22H 2O) with 0.343 mg, maximum, tin chloride [stannous and stannic] dihydrate as SnCl 22H 2O, and the following inactive ingredients: 0.84 mg gentisic acid as a stabilizer and 30 mg sodium chloride. The pH is adjusted with hydrochloric acid and/or sodium hydroxide. The pH of the radiolabeled drug is between 4.0 and 5.5. The vial contains a sterile, non-pyrogenic, lyophilized powder packaged under nitrogen. The chemical structure of oxidronate sodium is. The structure of the technetium Tc 99m oxidronate complex is unknown.</Description>
</NDC>
<NDC>
<NDCCode>69945-092-20</NDCCode>
<PackageDescription>5 VIAL in 1 CELLO PACK (69945-092-20) > 10 mL in 1 VIAL</PackageDescription>
<NDC11Code>69945-0092-20</NDC11Code>
<ProductNDC>69945-092</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Technetium Tc 99m Sestamibi</ProprietaryName>
<NonProprietaryName>Technetium Tc 99m Sestamibi</NonProprietaryName>
<DosageFormName>INJECTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20111031</StartMarketingDate>
<MarketingCategoryName>ANDA</MarketingCategoryName>
<ApplicationNumber>ANDA078098</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>TETRAKIS(2-METHOXYISOBUTYLISOCYANIDE)COPPER(I) TETRAFLUOROBORATE</SubstanceName>
<StrengthNumber>1</StrengthNumber>
<StrengthUnit>mg/mL</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2022-06-01</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20111031</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>Myocardial Imaging: Kit for the Preparation of Technetium Tc99m Sestamibi Injection is a myocardial perfusion agent that is indicated for detecting coronary artery disease by localizing myocardial ischemia (reversible defects) and infarction (non-reversible defects), in evaluating myocardial function and developing information for use in patient management decisions. Technetium Tc99m Sestamibi evaluation of myocardial ischemia can be accomplished with rest and cardiovascular stress techniques (e.g., exercise or pharmacologic stress in accordance with the pharmacologic stress agent's labeling). It is usually not possible to determine the age of a myocardial infarction or to differentiate a recent myocardial infarction from ischemia. Breast Imaging: Kit for the Preparation of Technetium Tc99m Sestamibi Injection is indicated for planar imaging as a second line diagnostic drug after mammography to assist in the evaluation of breast lesions in patients with an abnormal mammogram or a palpable breast mass. Kit for the Preparation of Technetium Tc99m Sestamibi Injection is not indicated for breast cancer screening, to confirm the presence or absence of malignancy, and it is not an alternative to biopsy.</IndicationAndUsage>
<Description>Each 10 mL vial contains a sterile, non-pyrogenic, lyophilized mixture of: 1 Tetrakis (2-methoxy isobutyl isonitrile) Copper (I) tetrafluoroborate – 1 mg, 2 Sodium Citrate Dihydrate - 2.6 mg, 3 L-Cysteine Hydrochloride Monohydrate – 1 mg, 4 Mannitol - 20 mg, 5 Stannous Chloride, Dihydrate, minimum (SnCl22H2O) - 0.025 mg, 6 Stannous Chloride, Dihydrate (SnCl22H2O) - 0.075 mg, 7 Tin Chloride (stannous and stannic) Dihydrate, maximum (as SnCl22H2O) - 0.086 mg.</Description>
</NDC>
<NDC>
<NDCCode>69945-092-40</NDCCode>
<PackageDescription>30 VIAL in 1 CARTON (69945-092-40) > 10 mL in 1 VIAL</PackageDescription>
<NDC11Code>69945-0092-40</NDC11Code>
<ProductNDC>69945-092</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Technetium Tc 99m Sestamibi</ProprietaryName>
<NonProprietaryName>Technetium Tc 99m Sestamibi</NonProprietaryName>
<DosageFormName>INJECTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20111031</StartMarketingDate>
<MarketingCategoryName>ANDA</MarketingCategoryName>
<ApplicationNumber>ANDA078098</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>TETRAKIS(2-METHOXYISOBUTYLISOCYANIDE)COPPER(I) TETRAFLUOROBORATE</SubstanceName>
<StrengthNumber>1</StrengthNumber>
<StrengthUnit>mg/mL</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2022-06-01</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20111031</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>Myocardial Imaging: Kit for the Preparation of Technetium Tc99m Sestamibi Injection is a myocardial perfusion agent that is indicated for detecting coronary artery disease by localizing myocardial ischemia (reversible defects) and infarction (non-reversible defects), in evaluating myocardial function and developing information for use in patient management decisions. Technetium Tc99m Sestamibi evaluation of myocardial ischemia can be accomplished with rest and cardiovascular stress techniques (e.g., exercise or pharmacologic stress in accordance with the pharmacologic stress agent's labeling). It is usually not possible to determine the age of a myocardial infarction or to differentiate a recent myocardial infarction from ischemia. Breast Imaging: Kit for the Preparation of Technetium Tc99m Sestamibi Injection is indicated for planar imaging as a second line diagnostic drug after mammography to assist in the evaluation of breast lesions in patients with an abnormal mammogram or a palpable breast mass. Kit for the Preparation of Technetium Tc99m Sestamibi Injection is not indicated for breast cancer screening, to confirm the presence or absence of malignancy, and it is not an alternative to biopsy.</IndicationAndUsage>
<Description>Each 10 mL vial contains a sterile, non-pyrogenic, lyophilized mixture of: 1 Tetrakis (2-methoxy isobutyl isonitrile) Copper (I) tetrafluoroborate – 1 mg, 2 Sodium Citrate Dihydrate - 2.6 mg, 3 L-Cysteine Hydrochloride Monohydrate – 1 mg, 4 Mannitol - 20 mg, 5 Stannous Chloride, Dihydrate, minimum (SnCl22H2O) - 0.025 mg, 6 Stannous Chloride, Dihydrate (SnCl22H2O) - 0.075 mg, 7 Tin Chloride (stannous and stannic) Dihydrate, maximum (as SnCl22H2O) - 0.086 mg.</Description>
</NDC>
<NDC>
<NDCCode>69945-094-20</NDCCode>
<PackageDescription>5 VIAL in 1 CELLO PACK (69945-094-20) / 10 mL in 1 VIAL (69945-094-01) </PackageDescription>
<NDC11Code>69945-0094-20</NDC11Code>
<ProductNDC>69945-094</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Technescan Pyp</ProprietaryName>
<NonProprietaryName>Technetium Tc 99m Pyrophosphate</NonProprietaryName>
<DosageFormName>INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>20151014</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA017538</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>SODIUM PYROPHOSPHATE; STANNOUS CHLORIDE</SubstanceName>
<StrengthNumber>11.9; 3.2</StrengthNumber>
<StrengthUnit>mg/10mL; mg/10mL</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2025-12-16</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>20151014</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>Technescan PYP, after radiolabeling with sodium pertechnetate Tc 99m, is indicated for: Skeletal imaging to demonstrate areas of altered osteogenesis in adults Cardiac imaging as an adjunct in the diagnosis of acute myocardial infarction in adults (See WARNINGS). Technescan PYP, in conjunction with sodium pertechnetate Tc 99m injection for red blood cell (RBC) labeling, is indicated for gated cardiac blood pool imaging and for the detection of gastrointestinal bleeding sites in adults.</IndicationAndUsage>
<Description>Drug Characteristics Technescan PYP (kit for the preparation of technetium Tc 99m pyrophosphate injection) is a radioactive diagnostic drug for intravenous use after radiolabeling with sodium pertechnetate Tc 99m injection or after reconstitution with 0.9% sodium chloride injection in conjunction with sodium pertechnetate Tc 99m injection. Each vial contains 11.9 mg sodium pyrophosphate, 3.2 mg (minimum) stannous chloride (SnCl 22H 2O), and 4.4 mg (maximum) total tin expressed as stannous chloride (SnCl 22H 2O). Prior to lyophilization, the pH is adjusted with hydrochloric acid. The pH of the reconstituted drug is between 4.5 and 7.5. No bacteriostatic preservative is present. The vial contains a sterile, non-pyrogenic, lyophilized powder packaged under nitrogen. The precise structures of the stannous-pyrophosphate and technetium Tc 99m pyrophosphate complexes are not known.</Description>
</NDC>
<NDC>
<NDCCode>69945-096-20</NDCCode>
<PackageDescription>5 VIAL in 1 CELLO PACK (69945-096-20) / 1 INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION in 1 VIAL</PackageDescription>
<NDC11Code>69945-0096-20</NDC11Code>
<ProductNDC>69945-096</ProductNDC>
<ProductTypeName>HUMAN PRESCRIPTION DRUG</ProductTypeName>
<ProprietaryName>Technescan Mag3</ProprietaryName>
<NonProprietaryName>Technescan Tc 99m Mertiatide</NonProprietaryName>
<DosageFormName>INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION</DosageFormName>
<RouteName>INTRAVENOUS</RouteName>
<StartMarketingDate>19900615</StartMarketingDate>
<MarketingCategoryName>NDA</MarketingCategoryName>
<ApplicationNumber>NDA019882</ApplicationNumber>
<LabelerName>Curium US LLC</LabelerName>
<SubstanceName>BETIATIDE</SubstanceName>
<StrengthNumber>1</StrengthNumber>
<StrengthUnit>mg/1</StrengthUnit>
<Status>Active</Status>
<LastUpdate>2026-01-08</LastUpdate>
<PackageNdcExcludeFlag>N</PackageNdcExcludeFlag>
<ProductNdcExcludeFlag>N</ProductNdcExcludeFlag>
<ListingRecordCertifiedThrough>20271231</ListingRecordCertifiedThrough>
<StartMarketingDatePackage>19900615</StartMarketingDatePackage>
<SamplePackage>N</SamplePackage>
<IndicationAndUsage>Technetium Tc 99m mertiatide is a renal imaging agent for use in the diagnosis of congenital and acquired abnormalities, renal failure, urinary tract obstruction, and calculi in adults and pediatric patients. (See Pediatric Use.) It is a diagnostic aid in providing renal function, split function, renal angiograms, and renogram curves for whole kidney and renal cortex.</IndicationAndUsage>
<Description>Technescan MAG3 is a kit for the preparation of technetium Tc 99m mertiatide, a diagnostic radiopharmaceutical. It is supplied as a sterile, nonpyrogenic, lyophilized powder. Each vial contains betiatide (N-[N-[N-[(benzoylthio) acetyl]glycyl]glycyl]-glycine). After reconstitution with sterile sodium pertechnetate Tc 99m injection, the technetium Tc 99m mertiatide (disodium[N-[N-[N-(mercaptoacetyl) glycyl]glycyl] glycinato (2-) - N,N′,N″,S′]oxotechnetate (2-)) which is formed is suitable for intravenous administration. Each 10 milliliter vial contains 1 milligram betiatide, 0.05 milligram (minimum) stannous chloride dihydrate (SnCl 22H 2O) and 0.2 milligram (maximum) total tin expressed as stannous chloride dihydrate (SnCl 22H 2O), 40 milligrams sodium tartrate dihydrate (Na 2C 4H 2O 62H 2O), and 20 milligrams lactose monohydrate. Prior to lyophilization, sodium hydroxide or hydrochloric acid may be added for pH adjustment. The pH of the reconstituted drug is between 5.0 and 6.0. No bacteriostatic preservative is present. The contents are sealed under argon. Betiatide is light sensitive and must be protected from light. Betiatide and technetium Tc 99m mertiatide have the following structural formulas:.</Description>
</NDC>
</NDCList>